Fuel and gas
Subsidiaries provide fuel storage tank leasing and terminal services (Senoko Services) and gas shipping and retail (Senoko Gas Supply).
Senoko is best known for two uses, its power station and a fishery port, so large power plant and wholesale seafood handling share the same stretch of Sembawang's northern coastline. Classified areas centre on the power station's gas systems and on fuel storage tank leasing and terminal services, not on the whole estate. This page explains what to look for in a rugged mobile phone for Senoko, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Senoko: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ingress protection | IP65 to IP68 sealing | IP68 design |
| Drop and shock | A stated drop height onto concrete | Specification on request |
| Explosion protection | A separate certificate and marking | In progress; not issued |
| Where it applies | Senoko: Power plant gas and fuel systems, Fuel storage tanks and terminal services | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Senoko Industrial Zone. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
Subsidiaries provide fuel storage tank leasing and terminal services (Senoko Services) and gas shipping and retail (Senoko Gas Supply).
Senoko Power Station is a combined cycle plant with a licensed capacity of 2,644 MW and supplies about 20 per cent of Singapore's electricity needs, according to its operator.
Senoko Power Station is the largest power station in Singapore and was commissioned in 1976, after planning began in the early 1970s under the Public Utilities Board.
Its authorised capacity is 2,800 megawatts from seven operating units, and it runs mainly as a combined-cycle gas plant, so gas-turbine halls and fuel systems form its main classified areas.
Natural gas supplies over 90 percent of Singapore's electricity, up from less than 20 percent in 2000, which is why large gas-fired plants such as Senoko dominate the local hazardous-area picture.
Combined-cycle units 6 and 7, rated at 431 megawatts each, were completed by 2012 by repowering the second oil-fired steam stage, while units 3 to 5 at 365 megawatts each followed by 2004.
A rugged phone is built to survive water, dust, drops and rough handling, usually rated by an IP code and a drop specification. Ruggedness is an environmental property: it says nothing about whether a phone may be used where flammable gas or dust is present. That is decided by explosion-protection certification and marking.
The IS-04Z1 combines both: an IP68 sealed rugged build and a design for Zone 1 and Zone 21 (marking target Ex ib IIC T4). The explosion-protection certificates are in progress and none has been issued.
In Senoko. Senoko sits on the northern coast of Singapore, so warm, humid and salty air and heavy tropical rain are routine for outdoor staff. IP68 water and dust protection is designed in for the IS-04Z1 and helps with those conditions. It does not provide explosion protection, which depends on Ex certification, currently in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
It is designed to IP68 sealing, with glove-friendly controls. Ruggedness is not explosion protection: that depends on the certificates, which are in progress.
Likely candidates are power plant gas and fuel systems, fuel storage tanks and terminal services. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Combined-cycle units are taken offline for planned inspections, and contractor numbers rise during those windows. Dates are set by the operator and the grid, so ask the plant's maintenance planner about the outage calendar and the approved-equipment list.
Natural gas has been the main fuel since 1992, with fuel oil as a back-up. Gas groups and temperature classes differ between natural gas and oil vapour, so devices should be matched to the gas group and temperature class stated in the plant's area classification.
No. The classified areas are mostly the gas and fuel systems and fuel tanks at the power station, not the estate as a whole. Other tenants have not been checked here. Ask the relevant operator for its classification before assuming a zone, and confirm with the site operator.