Ownership
Senoko Energy lists Marubeni Corporation and Sembcorp Industries as its shareholders.
Senoko is an industrial subzone of Sembawang on Singapore's northern coast, best known for Senoko Power Station. Senoko Power Station is the largest power station in Singapore and was commissioned in 1976, after planning began in the early 1970s under the Public Utilities Board. This page explains what to look for in an explosion proof mobile phone for Senoko, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Senoko: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Protection concept | Flameproof (Ex d) or intrinsic safety (Ex i) | Intrinsic safety, level ib |
| Zone suitability | Zone 1 gas and Zone 21 dust | Design target for Zone 1 and 21 |
| Certificate | Number, issuing body and schedule of conditions | In progress; not issued |
| Where it applies | Senoko: Power plant gas and fuel systems, Fuel storage tanks and terminal services | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Senoko Industrial Zone. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
Senoko Energy lists Marubeni Corporation and Sembcorp Industries as its shareholders.
Subsidiaries provide fuel storage tank leasing and terminal services (Senoko Services) and gas shipping and retail (Senoko Gas Supply).
Combined-cycle units 6 and 7, rated at 431 megawatts each, were completed by 2012 by repowering the second oil-fired steam stage, while units 3 to 5 at 365 megawatts each followed by 2004.
The station stands on the site of a former British naval base in Sembawang on Singapore's northern coast, so the shoreline is a mixture of old naval and new industrial land.
Natural gas has replaced crude oil as the main fuel since 1992, with fuel oil kept as a back-up, and stage III boilers were modified with gas burners to burn either fuel.
Senoko is best known for two uses, its power station and a fishery port, so large power plant and wholesale seafood handling share the same stretch of Sembawang's northern coastline.
“Explosion proof” is the phrase most buyers use for equipment that may be taken into a classified hazardous area. Strictly, it covers several protection concepts: a flameproof enclosure (Ex d) contains an internal explosion, while intrinsic safety (Ex i) limits electrical energy so that an ignition cannot start. Phones are normally intrinsically safe, because a flameproof handset would be too heavy to carry all shift.
The IS-04Z1 uses intrinsic safety, with a marking target of Ex ib IIC T4, and is designed for Zone 1 and Zone 21. It is pre-launch, certification is in progress and no certificate has been issued.
In Senoko. At a gas and diesel power station the phrase explosion-proof can mislead. Flameproof Ex d housings suit fixed items such as motors and junction boxes, while a handheld phone relies on intrinsic safety to keep energy below ignition level. The IS-04Z1 is designed around intrinsic safety, with certification still in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
It is intrinsically safe (marking target Ex ib IIC T4), which is the usual way to make a phone for hazardous areas. It is not a flameproof (Ex d) design, and certification is still in progress.
Likely candidates are power plant gas and fuel systems, fuel storage tanks and terminal services. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Combined-cycle units are taken offline for planned inspections, and contractor numbers rise during those windows. Dates are set by the operator and the grid, so ask the plant's maintenance planner about the outage calendar and the approved-equipment list.
Natural gas has been the main fuel since 1992, with fuel oil as a back-up. Gas groups and temperature classes differ between natural gas and oil vapour, so devices should be matched to the gas group and temperature class stated in the plant's area classification.
No. The classified areas are mostly the gas and fuel systems and fuel tanks at the power station, not the estate as a whole. Other tenants have not been checked here. Ask the relevant operator for its classification before assuming a zone, and confirm with the site operator.
Related guides for Senoko Industrial Zone and for Singapore.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.