Senoko is an industrial subzone of Sembawang on Singapore's northern coast, best known for Senoko Power Station. Classified areas centre on the power station's gas systems and on fuel storage tank leasing and terminal services, not on the whole estate. If you are specifying an industrial mobile phone for Senoko, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Senoko Industrial Zone, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicindustrial
DeviceMobile Phone
RouteSpecification
WhereSenoko Industrial Zone

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Senoko: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · industrial

Checklist: industrial mobile phone for Senoko

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
Ingress protectionIP rating for dust and waterIP68 design
Fleet managementEMM and MDM supportAndroid 16 with EMM and MDM
Explosion protectionA separate certificate and markingIn progress; not issued
Where it appliesSenoko: Power plant gas and fuel systems, Fuel storage tanks and terminal servicesClassified by the site operator
Product · Senoko Industrial Zone

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Senoko Industrial Zone. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Senoko

Working in Senoko: operators and classified areas

The companies on site and the hazardous-area types a handset is likely to meet there.

Operators and companies on site

  • Senoko Energy
  • Senoko Services (fuel storage tank leasing and terminals)
  • Senoko Gas Supply

Classified areas to expect

  • Power plant gas and fuel systems
  • Fuel storage tanks and terminal services
Local conditions · Senoko

What Senoko means for portable equipment

Power station

Senoko Power Station is a combined cycle plant with a licensed capacity of 2,644 MW and supplies about 20 per cent of Singapore's electricity needs, according to its operator.

Ownership

Senoko Energy lists Marubeni Corporation and Sembcorp Industries as its shareholders.

Field notes · Senoko

More about Senoko that matters for portable equipment

Senoko: industry on the ground

Senoko Power Station is the largest power station in Singapore and was commissioned in 1976, after planning began in the early 1970s under the Public Utilities Board.

Senoko: infrastructure

Its authorised capacity is 2,800 megawatts from seven operating units, and it runs mainly as a combined-cycle gas plant, so gas-turbine halls and fuel systems form its main classified areas.

Senoko: industry on the ground

Natural gas supplies over 90 percent of Singapore's electricity, up from less than 20 percent in 2000, which is why large gas-fired plants such as Senoko dominate the local hazardous-area picture.

Senoko: infrastructure

Combined-cycle units 6 and 7, rated at 431 megawatts each, were completed by 2012 by repowering the second oil-fired steam stage, while units 3 to 5 at 365 megawatts each followed by 2004.

The term · industrial

What “industrial” means for a smartphone

“Industrial” describes a phone built for plant conditions: sealed, drop-resistant and manageable at fleet scale through Android Enterprise. It does not by itself mean the phone may enter a classified area. Only a device with a valid explosion-protection certificate and marking may do that.

The IS-04Z1 is designed to be both an industrial Android phone (IP68, 4,000 mAh battery, 50 MP camera, Android 16 with EMM and MDM support) and an intrinsically safe one. Its explosion-protection certificates are in progress and have not been issued.

In Senoko. A plant of this scale runs shift crews plus outage contractors, so a shared pool of handhelds under EMM or MDM suits it. Enrolment, app lists and lock-down policies should be set before devices reach site. Charging belongs in a safe area such as a control room, and connectivity rules are the plant's.

The route · specification

Specifying an industrial mobile phone for Senoko Industrial Zone

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Senoko Industrial Zone

Frequently asked questions

Can we buy an industrial mobile phone in Senoko Industrial Zone today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an industrial mobile phone in Senoko Industrial Zone cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

Is the IS-04Z1 an industrial phone as well as an Ex phone?

Yes by design: IP68 sealing, a 4,000 mAh battery, a 50 MP camera and Android 16 with EMM and MDM support. The explosion-protection certificates are separate and still in progress.

Which areas at Senoko would use it?

Likely candidates are power plant gas and fuel systems, fuel storage tanks and terminal services. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

When are outages most likely to need extra field devices?

Combined-cycle units are taken offline for planned inspections, and contractor numbers rise during those windows. Dates are set by the operator and the grid, so ask the plant's maintenance planner about the outage calendar and the approved-equipment list.

Does the fuel mix change the equipment requirement?

Natural gas has been the main fuel since 1992, with fuel oil as a back-up. Gas groups and temperature classes differ between natural gas and oil vapour, so devices should be matched to the gas group and temperature class stated in the plant's area classification.

Is the whole Senoko estate a hazardous area?

No. The classified areas are mostly the gas and fuel systems and fuel tanks at the power station, not the estate as a whole. Other tenants have not been checked here. Ask the relevant operator for its classification before assuming a zone, and confirm with the site operator.

Enquiry · Senoko

Ask about the IS-04Z1 for Senoko, Singapore

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · Senoko

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Senoko Industrial Zone?

Name the site and the operator and we will send what is available before launch.