Liquid terminal
Wikipedia describes a liquid terminal of 97 tanks holding 425,000 kilolitres for crude oil, chemicals and edible oils.
Mundra is a multipurpose private port and Special Economic Zone on the Gulf of Kutch in Gujarat, operated by Adani Ports and SEZ. Its liquid terminal and LNG import terminal create hazardous areas around tanks, jetties and regasification plant. This page explains what to look for in an intrinsically safe smartphone for Mundra, Gujarat, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Mundra, Gujarat: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Level of protection | ia, ib or ic matched to the zone | ib, for Zone 1 |
| Entity parameters | Uo, Io and Po within the device limits | Published with the certificate |
| Accessories | Chargers and cases certified with the device | Defined at certification |
| Where it applies | Mundra, Gujarat: Liquid chemical and oil tank terminal, LNG regasification terminal, Tanker jetties | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Mundra India. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The companies on site and the hazardous-area types a handset is likely to meet there.
Wikipedia describes a liquid terminal of 97 tanks holding 425,000 kilolitres for crude oil, chemicals and edible oils.
The Mundra LNG terminal is run by GSPC LNG Limited, a joint venture of GSPC and Adani Enterprises, with a first-phase capacity of 5 million tonnes a year completed in October 2018.
A private rail network of 117 kilometres links Mundra to Adipur, with doubled track and double-stack container trains.
Mundra lies on the northern shore of the Gulf of Kutch in Kutch district, Gujarat, on major westbound maritime routes.
It is India's first private port, with berths operating from 1998 and a concession signed in 2001, so it is a comparatively modern facility.
Mundra is India's first multi-product port-based special economic zone, with a notified area of 6,473 hectares and a planned area of 135 square kilometres.
Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.
The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.
In Mundra, Gujarat. Rounds across a large number of storage tanks, tanker jetties and pipeline terminals involve many gauge readings, checks and photographs. An intrinsically safe handheld supports that work in place. The IS-04Z1 is designed for it, though certification is still in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.
Likely candidates are liquid chemical and oil tank terminal, lng regasification terminal, tanker jetties, pipeline terminals. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
The notified multi-product zone covers 6,473 hectares, with a planned area of 135 square kilometres. Many companies operate inside it, each with its own site rules.
The nearby Kandla area has low rainfall of about 322 millimetres a year and April and May maxima around 40 degrees Celsius. Dust and salt air are likely, so check ingress and corrosion ratings.
Crude oil and chemicals matter most because they create hazardous areas around tanks and jetties, and LNG adds light-gas areas. Edible oils are generally less hazardous. The classification record for each area decides, so ask the terminal operator for its gas groups and temperature classes.
Other guides for Mundra India, other places in India, and the pages behind them.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.