Port and SEZ
Mundra is a multi-product port-based SEZ with rail, highway and pipeline links, so several industrial operators share the area.
Agreements signed in 2002 and later cover crude oil handling for refinery customers, and a single-point mooring became operational in late 2005. Its liquid terminal and LNG import terminal create hazardous areas around tanks, jetties and regasification plant. If you are specifying an Ex-proof mobile phone for Mundra, Gujarat, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Mundra, Gujarat: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | Mundra, Gujarat: Liquid chemical and oil tank terminal, LNG regasification terminal, Tanker jetties | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Mundra India. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The companies on site and the hazardous-area types a handset is likely to meet there.
Mundra is a multi-product port-based SEZ with rail, highway and pipeline links, so several industrial operators share the area.
Wikipedia describes a liquid terminal of 97 tanks holding 425,000 kilolitres for crude oil, chemicals and edible oils.
Mundra is India's largest commercial and container port, handling over 155 million tonnes a year, about 11 percent of India's maritime cargo and nearly a third of its container traffic.
The Gulf of Kutch coast to the west, such as at Kandla, is hot and dry, with April and May maxima around 40 degrees Celsius and low rainfall.
The port is designed for containers, dry bulk, break bulk, liquid cargo and automobiles, so a wide mix of hazards exists across terminals.
A private rail network of 117 kilometres links Mundra to Adipur, with doubled track and double-stack container trains.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In Mundra, Gujarat. A marking check at Mundra should compare the device against the cargo: crude oil and chemicals may be classified, while edible oils are generally less hazardous. LNG areas involve light gas. The IS-04Z1 target marking is II 2 G Ex ib IIC T4, and the operator's classification decides suitability.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
Likely candidates are liquid chemical and oil tank terminal, lng regasification terminal, tanker jetties, pipeline terminals. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
The notified multi-product zone covers 6,473 hectares, with a planned area of 135 square kilometres. Many companies operate inside it, each with its own site rules.
The nearby Kandla area has low rainfall of about 322 millimetres a year and April and May maxima around 40 degrees Celsius. Dust and salt air are likely, so check ingress and corrosion ratings.
Crude oil and chemicals matter most because they create hazardous areas around tanks and jetties, and LNG adds light-gas areas. Edible oils are generally less hazardous. The classification record for each area decides, so ask the terminal operator for its gas groups and temperature classes.
More on Mundra India, and on other places in India.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Name the site and the operator and we will send what is available before launch.