Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Batam Shipyard · intrinsically safe

Intrinsically Safe Smartphone in Batam Shipyard

Batam, in the Riau Islands, has a large cluster of shipyards and offshore fabrication yards, concentrated around Tanjung Uncang on the western side of the island. Painting, tank cleaning, gas freeing and hot work on vessels and offshore modules create temporary hazardous areas. This page explains what to look for in an intrinsically safe smartphone for Batam shipyards, Riau Islands, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Batam Shipyard, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicintrinsically safe
DeviceSmartphone
RouteSpecification
WhereBatam Shipyard

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Batam shipyards, Riau Islands: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · intrinsically safe

Checklist: intrinsically safe smartphone for Batam shipyards, Riau Islands

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
Level of protectionia, ib or ic matched to the zoneib, for Zone 1
Entity parametersUo, Io and Po within the device limitsPublished with the certificate
AccessoriesChargers and cases certified with the deviceDefined at certification
Where it appliesBatam shipyards, Riau Islands: Vessel tank and cargo spaces, Paint and coating shops, Fuel and gas storageClassified by the site operator
Product · Batam Shipyard

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Batam Shipyard. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Batam shipyards, Riau Islands

Batam shipyards, Riau Islands at a glance: who is there, what is classified

A short profile of the site and the kinds of classified area that matter for portable equipment.

Operators and companies on site

  • PT Batamec Shipyard
  • PT McDermott Indonesia
  • PT SMOE Indonesia

Classified areas to expect

  • Vessel tank and cargo spaces
  • Paint and coating shops
  • Fuel and gas storage
  • Offshore module fabrication areas
Local conditions · Batam shipyards, Riau Islands

Site conditions at Batam shipyards, Riau Islands: what wears and what limits equipment

Large cluster

A recruitment-sector analysis puts the number of yards on Batam at roughly 130, so conditions vary from yard to yard.

Example yard

PT Batamec in Tanjung Uncang was founded in 1986, was acquired by PT Teknologi Global Indonesia in March 2024, and occupies a 97-hectare site with a graving dock and slipways.

Field notes · Batam shipyards, Riau Islands

More about Batam shipyards, Riau Islands that matters for portable equipment

Batam shipyards, Riau Islands: who works there

Citra Shipyard, founded in 2006, runs two Batam yards: a 42 hectare site at Kabil and a 24 hectare site at Kampung Becek, building barges, tugs, tankers and offshore supply vessels.

Batam shipyards, Riau Islands: geography and layout

Batam is an industrial island about 20 km off Singapore's south coast, within a free trade zone in the Indonesia-Malaysia-Singapore Growth Triangle, which makes it a convenient base for marine contractors serving regional yards.

Batam shipyards, Riau Islands: climate and equipment wear

Batam has a tropical rainforest climate with heavy rainfall all year, so yard equipment faces constant humidity and frequent downpours rather than a dry season.

Batam shipyards, Riau Islands: people and language

Two thirds of Batam's population are migrants, and Indonesian is the common working language, with Malay widely understood by visiting contractors from Singapore and Johor.

The term · intrinsically safe

What “intrinsically safe” means for a smartphone

Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.

The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.

In Batam shipyards, Riau Islands. Shipyard work moves between vessel tank spaces, coating shops and module fabrication areas, often under permit. A handheld designed for intrinsically safe use could carry inspection checklists and photographs into those spaces. That depends on certification and on each yard's acceptance of the device.

The route · specification

Specifying an intrinsically safe smartphone for Batam Shipyard

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Batam Shipyard

Frequently asked questions

Can we buy an intrinsically safe smartphone in Batam Shipyard today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an intrinsically safe smartphone in Batam Shipyard cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

What does ‘intrinsically safe’ mean for the IS-04Z1?

The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.

Which areas at Batam shipyards, Riau Islands would use it?

Likely candidates are vessel tank and cargo spaces, paint and coating shops, fuel and gas storage, offshore module fabrication areas. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Do offshore fabrication and repair jobs in Batam involve different rules from newbuilds?

They can. Repair and offshore conversion often involve ships that have carried fuel or chemicals, which raises the chance of residual vapours, so gas testing and permit-to-work control are usually stricter. Ask the yard for its tank-entry and hot-work procedures.

Why is humidity a concern for phones used in Batam yards?

Heavy rainfall all year and a tropical rainforest climate mean constant moisture, so devices typically need good ingress protection, sealed charging contacts and regular drying and cleaning. Check the rating and charging method against the yard's safety rules.

Is a handset used in a vessel tank space always treated as hazardous-area equipment?

Not always, but during painting, tank cleaning, gas freeing or hot work the space is usually treated as hazardous. The yard's gas-free procedure and permit decide. Do not take a non-Ex device into such a space unless the permit explicitly allows it.

Enquiry · Batam shipyards, Riau Islands

Ask about the IS-04Z1 for Batam shipyards, Riau Islands, Indonesia

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · Batam shipyards, Riau Islands

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Batam Shipyard?

Name the site and the operator and we will send what is available before launch.