Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Singapore Marine · IECEx

IECEx Mobile Phone in Singapore Marine

Seatrium's Tuas Boulevard Yard has a graving dock about 350 metres long and 66 metres wide, which can take very large tankers and floating production units. Tank work, repair and conversion create Zone 1 conditions on vessels. This page explains what to look for in an IECEx mobile phone for Singapore marine and shipyard sector, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Singapore Marine, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicIECEx
DeviceMobile Phone
RouteSpecification
WhereSingapore Marine

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Singapore marine and shipyard sector: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · IECEx

Checklist: IECEx mobile phone for Singapore marine and shipyard sector

Checks a reviewer should make, with the IS-04Z1 position
CheckWhat to look forIS-04Z1 today
Certificate of conformityNumber checkable on the IECEx online registerIn progress; not issued
Standards editionThe IEC 60079 edition the certificate citesStated on the certificate when issued
Schedule of conditionsLimits of use, batteries and accessoriesPublished with the certificate
Where it appliesSingapore marine and shipyard sector: Vessel tank and cargo spaces, Repair and conversion work, Paint and coating areasClassified by the site operator
Product · Singapore Marine

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Singapore Marine. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Singapore marine and shipyard sector

Working in Singapore marine and shipyard sector: operators and classified areas

The companies on site and the hazardous-area types a handset is likely to meet there.

Operators and companies on site

  • Seatrium
  • ST Engineering

Classified areas to expect

  • Vessel tank and cargo spaces
  • Repair and conversion work
  • Paint and coating areas
  • Offshore unit conversion
Local conditions · Singapore marine and shipyard sector

Site conditions at Singapore marine and shipyard sector: what wears and what limits equipment

Yard locations

Seatrium's Singapore yards are listed at Admiralty, Benoi, Pioneer, Tuas and Tuas Boulevard; ST Engineering operates the Gul and Benoi yards.

Merger

Seatrium describes itself as formed from the 2023 merger of Sembcorp Marine and Keppel Offshore & Marine, so older references to separate yards under those names are out of date.

Field notes · Singapore marine and shipyard sector

More about Singapore marine and shipyard sector that matters for portable equipment

Singapore marine and shipyard sector: climate and equipment wear

Heat, humidity and heavy showers are constant, so shipyard crews and handheld devices face both corrosion and moisture ingress year round.

Singapore marine and shipyard sector: projects and investment

Repair scope includes LNG and LPG carriers, cruise ships and ferries, floating production vessels, jack-ups, tankers, container ships and heavy-lift vessels, as well as jumboisation work.

Singapore marine and shipyard sector: infrastructure

Seatrium's Singapore ship repair yards are Admiralty, Benoi, Pioneer, Tuas and Tuas Boulevard, with offshore-specific Crescent and Pandan yards in addition.

Singapore marine and shipyard sector: logistics and access

Tuas Port, opened in September 2022, is planned to handle 65 million TEU a year in the 2040s, moving more container traffic to the western end of the island.

The term · IECEx

What “IECEx” means for a smartphone

IECEx is the international scheme for certifying equipment used in explosive atmospheres. A certificate of conformity is issued by an accredited certification body against a specific edition of the IEC 60079 standards and carries a schedule of conditions of safe use. It is not a legal requirement in most countries on its own, but many national schemes accept it as the technical basis.

The IECEx certificate for the IS-04Z1 is in progress and has not been issued. The marking target is Ex ib IIC T4, the intrinsic safety concept for Zone 1 gas with the hardest gas group (IIC) and a 135 °C temperature class.

In Singapore marine and shipyard sector. Seatrium's yards handle vessels and offshore units owned by international operators, so visiting superintendents are likely to know IECEx. A certificate of conformity and its schedule of conditions are what they would want. Neither exists yet for the IS-04Z1, since the IECEx programme is still in progress.

The route · specification

Specifying an IECEx mobile phone for Singapore Marine

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Singapore Marine

Frequently asked questions

Can we buy an IECEx mobile phone in Singapore Marine today?

Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.

What does an IECEx mobile phone in Singapore Marine cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

Does the IS-04Z1 hold an IECEx certificate?

No. The IECEx certificate is in progress and has not been issued. SAMS will publish the number when it exists.

Which areas at Singapore marine and shipyard sector would use it?

Likely candidates are vessel tank and cargo spaces, repair and conversion work, paint and coating areas, offshore unit conversion. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

What makes marine hazardous areas different from onshore plants?

Zones move with the vessel's cargo, tank status and gas-free certification, so a space may be classified one day and safe the next. Always check the vessel's permit and gas-freeing status rather than relying on a fixed plan.

How can a supplier get onto a yard as a contractor?

Seatrium publishes its yard addresses, but access is normally arranged through a named project sponsor with induction, site pass and permit-to-work steps. Ask the sponsor which equipment certifications they accept before you ship devices.

Is a phone allowed inside a cargo tank on a vessel under repair?

Tank entry normally follows per-vessel gas-free and permit procedures set by the yard, and Zone 1 conditions are assumed in tank spaces. Only equipment with suitable certification would be considered, and the IS-04Z1 is not yet certified. Ask the yard safety team.

Enquiry · Singapore marine and shipyard sector

Ask about the IS-04Z1 for Singapore marine and shipyard sector, Singapore

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Singapore marine and shipyard sector

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Singapore Marine?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.