Procurement base
Aramco's Dhahran office is responsible for registering companies located in Saudi Arabia, and also those in the UAE, Bahrain, Kuwait, Oman, Qatar, Iraq, Jordan, Syria, Egypt and Lebanon.
Dhahran lies about 15 km south of Dammam and forms part of the Dammam Metropolitan Area, home to an estimated 2.2 million people; the city itself had 143,936 residents in 2022. It is an administrative and engineering centre; the classified areas it serves are at oil and gas facilities elsewhere in the Eastern Province. If you are specifying an IECEx mobile phone for Dhahran, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Dhahran: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Certificate of conformity | Number checkable on the IECEx online register | In progress; not issued |
| Standards edition | The IEC 60079 edition the certificate cites | Stated on the certificate when issued |
| Schedule of conditions | Limits of use, batteries and accessories | Published with the certificate |
| Where it applies | Dhahran: Oil and gas facilities served from Dhahran, Fuel storage and handling | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Dhahran. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
Aramco's Dhahran office is responsible for registering companies located in Saudi Arabia, and also those in the UAE, Bahrain, Kuwait, Oman, Qatar, Iraq, Jordan, Syria, Egypt and Lebanon.
Aramco's headquarters and the King Fahd University of Petroleum and Minerals are here, so engineering and procurement decisions are concentrated in the city.
Dhahran Techno Valley hosts more than 20 multinational research centres and 65 deep-tech start-ups beside KFUPM, so pilot trials of new field equipment can be run close to the energy companies.
Dammam Well No. 7, the first commercially viable well in Saudi Arabia, was drilled on the rocky hills here in the 1930s and was still producing about 70 years later.
Saudi Arabia's Communications, Space and Technology Commission, based in Riyadh, handles radio type approval; certificates are renewed every two years and European documents are accepted.
Aramco's headquarters has been in Dhahran for around 90 years, following a 1933 concession agreement and the first commercial oil output in 1938.
IECEx is the international scheme for certifying equipment used in explosive atmospheres. A certificate of conformity is issued by an accredited certification body against a specific edition of the IEC 60079 standards and carries a schedule of conditions of safe use. It is not a legal requirement in most countries on its own, but many national schemes accept it as the technical basis.
The IECEx certificate for the IS-04Z1 is in progress and has not been issued. The marking target is Ex ib IIC T4, the intrinsic safety concept for Zone 1 gas with the hardest gas group (IIC) and a 135 °C temperature class.
In Dhahran. Because engineering and procurement decisions are concentrated in Dhahran, international EPCs and visiting contractors often present IECEx documents here before work starts at a field site. The certificate of conformity and schedule of conditions would be reviewed. For the IS-04Z1 they are targets only, as certification is in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
No. The IECEx certificate is in progress and has not been issued. SAMS will publish the number when it exists.
Likely candidates are oil and gas facilities served from dhahran, fuel storage and handling. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Generally no. Much of Dhahran is gated, including the Aramco headquarters, residential camp, the university and the air base. Access is controlled by each compound, so arrange a host, a visitor pass and any required induction through your client before travelling.
Dhahran Techno Valley, next to KFUPM, hosts research centres and start-ups and pilots technology alongside large energy companies. Whether a particular trial is possible depends on the host organisation and its safety approvals, so contact them directly.
Not for ordinary office work, since Dhahran is mainly an administrative centre. The need arises when staff visit oil and gas facilities elsewhere in the Eastern Province, or handle fuel storage. Check the area classification for the place the device will be used, not for the city where it is bought.
More on Dhahran, and on other places in Saudi Arabia.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.