Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Umm Al Nar Refinery · hazardous area

Hazardous Area Mobile Phone in Umm Al Nar Refinery

Umm Al Nar Island in Abu Dhabi hosted the UAE's first refinery, inaugurated in 1976, which processed up to 85,000 barrels a day at its peak. Umm Al Nar island lies next to the city of Abu Dhabi and has been enlarged by land reclamation and dredging, so the current shoreline differs from the original. If you are specifying a hazardous area mobile phone for Umm Al Nar (former ADNOC refinery), this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Umm Al Nar Refinery, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topichazardous area
DeviceMobile Phone
RouteSpecification
WhereUmm Al Nar Refinery

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Umm Al Nar (former ADNOC refinery): pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.

At a glance · hazardous area

Checklist: hazardous area mobile phone for Umm Al Nar (former ADNOC refinery)

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
Zone0, 1 or 2 for gas; 20, 21 or 22 for dustDesigned for Zone 1 and Zone 21
Gas groupIIA, IIB or IICIIC (target)
Area drawingThe operator's own classification drawingDecided by the site operator
Where it appliesUmm Al Nar (former ADNOC refinery): Decommissioned refinery process units (former), Site clearance and demolition works, Relocated process units being reassembled elsewhere in the UAEClassified by the site operator
Product · Umm Al Nar Refinery

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Umm Al Nar Refinery. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Umm Al Nar (former ADNOC refinery)

Umm Al Nar (former ADNOC refinery): where the IS-04Z1 would work

Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.

Operators and companies on site

  • ADNOC

Classified areas to expect

  • Decommissioned refinery process units (former)
  • Site clearance and demolition works
  • Relocated process units being reassembled elsewhere in the UAE
Local conditions · Umm Al Nar (former ADNOC refinery)

Conditions in Umm Al Nar (former ADNOC refinery) that affect handheld equipment

Equipment reused elsewhere

ADNOC says the refinery's processing units are being refurbished and reassembled at a location within the UAE, where more than 240 specialist staff will be employed.

Where hazardous-area demand sits

ADNOC says its downstream strategy is focused on the Ruwais refining and petrochemical complex, so buyers targeting refinery work should look there rather than at Umm Al Nar.

Field notes · Umm Al Nar (former ADNOC refinery)

More about Umm Al Nar (former ADNOC refinery) that matters for portable equipment

Umm Al Nar (former ADNOC refinery): background

The island gave its name to the Umm Al Nar Bronze Age culture of about 2600 to 2000 BCE, so it is better known archaeologically than as a refinery site.

Umm Al Nar (former ADNOC refinery): projects and investment

The protected archaeological site is fenced by a concrete wall of about 1,760 m, and it lies between a refinery and a sensitive military area, so works near it face heritage constraints.

Umm Al Nar (former ADNOC refinery): infrastructure

Access to the island is across a bridge and is restricted to pass holders, so any clearance or demolition crews need site passes arranged in advance.

Umm Al Nar (former ADNOC refinery): background

The first archaeological excavations in Abu Dhabi began at Umm Al Nar in 1959, twelve years before the UAE was founded.

The term · hazardous area

What “hazardous area” means for a smartphone

A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.

No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.

In Umm Al Nar (former ADNOC refinery). Umm Al Nar no longer hosts the UAE's operating Zone 1 refinery work, since ADNOC consolidated downstream refining and petrochemicals at Ruwais in the Al Dhafra region. Former process units, tank areas and equipment being dismantled may still carry residual classification, and the operator, not SAMS, decides it. Buyers seeking live refinery areas should look at Ruwais.

The route · specification

Specifying a hazardous area mobile phone for Umm Al Nar Refinery

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Umm Al Nar Refinery

Frequently asked questions

Can we buy a hazardous area mobile phone in Umm Al Nar Refinery today?

Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.

What does a hazardous area mobile phone in Umm Al Nar Refinery cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

Which hazardous areas is the IS-04Z1 designed for?

Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.

Which areas at Umm Al Nar (former ADNOC refinery) would use it?

Likely candidates are decommissioned refinery process units (former), site clearance and demolition works, relocated process units being reassembled elsewhere in the uae. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Why is access to Umm Al Nar island restricted?

The island is reached across a bridge restricted to pass holders. It also holds a protected archaeological site between a refinery and a sensitive military area, so public access is prohibited. Contractors need a pass arranged through the site owner or main contractor.

Is there still hazardous-area work at Umm Al Nar?

Possibly limited. The former refinery was shut in 2022, so current work is mainly decommissioning, clearance and site works, which can still involve residual hydrocarbons and gas-freeing. Confirm the current status and rules with the site owner before specifying devices.

Is there still hazardous-area work at Umm Al Nar?

ADNOC states that the refinery stopped operating in 2022 and the land is being redeveloped. Some clearance and demolition activity may involve residual classified areas, but live refinery work has moved on. Confirm with the site operator what classification, if any, still applies to a given work package.

Enquiry · Umm Al Nar (former ADNOC refinery)

Ask about the IS-04Z1 for Umm Al Nar (former ADNOC refinery), United Arab Emirates

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · Umm Al Nar (former ADNOC refinery)

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Umm Al Nar Refinery?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.