India: geography and layout
The largest crude reserves are in the Western Offshore region at 37 per cent and Assam at 27 per cent, so both offshore platforms and remote north-eastern fields matter.
The IS-04Z1 is designed for people who work inside classified areas at Indian refineries, gas plants, LNG jetties and API blocks: field operators, inspection engineers, shift in-charges, and the HSE and materials teams whose sign-off a device has to survive. If you are specifying a hazardous area cell phone for India, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for India: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Zone | 0, 1 or 2 for gas; 20, 21 or 22 for dust | Designed for Zone 1 and Zone 21 |
| Gas group | IIA, IIB or IIC | IIC (target) |
| Area drawing | The operator's own classification drawing | Decided by the site operator |
| Where it applies | India: Jamnagar, Gujarat, Dahej and the Gujarat PCPIR, Hazira and Surat | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in India. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS India market guide.
The largest crude reserves are in the Western Offshore region at 37 per cent and Assam at 27 per cent, so both offshore platforms and remote north-eastern fields matter.
Imports are applied for by an Indian service provider or distributor, and there is no separate PESO mark; the Ex marking and the approval letter show compliance.
India imports 82 per cent of its oil needs, so import terminals, tank farms and coastal refineries are central to supply.
India's first oil deposits were found near Digboi in Assam in 1889, and its gas industry began in the 1960s with discoveries in Assam and the Mumbai High field.
A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.
No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.
In India. Indian classified areas fall into two groups: the hydrocarbon chain, from coastal refineries to gas processing, LNG terminals and offshore platforms, and pharmaceutical plants where solvents classify rooms inside buildings. The operator classifies the areas, not SAMS. The device is designed for Zone 1 and Zone 21.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.
The market guide for India covers Jamnagar, Gujarat, Dahej and the Gujarat PCPIR, Hazira and Surat, Vadodara, Koyali, Ankleshwar, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
PESO approval is required for Ex electrical apparatus at petroleum, gas cylinder and pressure vessel premises, and imports are applied for through an Indian service provider or distributor. Whether it applies to a given site depends on the licensing category, so ask the site's safety team and a PESO consultant.
Typically the large coastal refineries such as Jamnagar, offshore platforms in the Western Offshore region, petrochemical and fertiliser complexes, and gas fields in Assam and Gujarat. Each operator issues its own area classification, so request the drawing, gas group and temperature class first.
The market guide lists PESO, BIS and WPC approvals as in progress, alongside IECEx. None has been granted yet. Which are needed for a given site depends on the operator and the regulator, so ask the site operator and check the current status before ordering.
More on India, and on other places in India.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.