Seatrium sites
Its official contact page lists Admiralty Yard, Benoi Yard, Pioneer Yard, Tuas Yard and Tuas Boulevard Yard in Singapore.
Singapore's major shipyards are run by Seatrium, with yards at Admiralty, Benoi, Pioneer, Tuas and Tuas Boulevard, and by ST Engineering. Heat, humidity and frequent heavy showers affect work on open decks, quays and docks all year round. If you are specifying an explosion proof smartphone for Singapore shipyards, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Singapore shipyards: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Protection concept | Flameproof (Ex d) or intrinsic safety (Ex i) | Intrinsic safety, level ib |
| Zone suitability | Zone 1 gas and Zone 21 dust | Design target for Zone 1 and 21 |
| Certificate | Number, issuing body and schedule of conditions | In progress; not issued |
| Where it applies | Singapore shipyards: Vessel tank spaces, Dry dock and repair work, Paint and coating shops | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Singapore Shipyard. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
Its official contact page lists Admiralty Yard, Benoi Yard, Pioneer Yard, Tuas Yard and Tuas Boulevard Yard in Singapore.
ST Engineering acquired the Gul yard in 2023 for ship repair, and keeps its Benoi yard mainly for shipbuilding.
In 2002 Keppel Shipyard was combined with Keppel FELS and Keppel Singmarine to form the Keppel Offshore and Marine group, which became part of Seatrium in 2023.
Seatrium lists its Singapore yards at Admiralty Road West, 15 Benoi Road, 50 Gul Road, 51 Pioneer Sector 1 and 80 Tuas South Boulevard, each with its own gate and switchboard.
Two large FPSOs, P-80 and P-82, were christened at the Tuas Boulevard Yard, each designed to produce 225,000 barrels of oil a day.
Pioneer Yard has a 1,400 metre quay with 8 to 10 metres of depth, with a second quay of 350 metres, giving long alongside berths for repair work.
“Explosion proof” is the phrase most buyers use for equipment that may be taken into a classified hazardous area. Strictly, it covers several protection concepts: a flameproof enclosure (Ex d) contains an internal explosion, while intrinsic safety (Ex i) limits electrical energy so that an ignition cannot start. Phones are normally intrinsically safe, because a flameproof handset would be too heavy to carry all shift.
The IS-04Z1 uses intrinsic safety, with a marking target of Ex ib IIC T4, and is designed for Zone 1 and Zone 21. It is pre-launch, certification is in progress and no certificate has been issued.
In Singapore shipyards. On a newbuild or repair job, explosion-proof is a loose term. Flameproof Ex d suits fixed fittings, while a handheld phone taken into a vessel tank depends on intrinsic safety. The IS-04Z1 is designed around intrinsic safety, with certification in progress and each yard's permit rules applying.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
It is intrinsically safe (marking target Ex ib IIC T4), which is the usual way to make a phone for hazardous areas. It is not a flameproof (Ex d) design, and certification is still in progress.
Likely candidates are vessel tank spaces, dry dock and repair work, paint and coating shops, offshore conversion. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Large graving docks hold very big vessels and many contractors at once, so crowding, crane lifts and hot work overlap. Hazardous-area controls are managed per vessel by the yard's safety team and the owner's representative.
Seatrium's yards at Admiralty, Benoi, Pioneer, Tuas and Tuas Boulevard are the large repair and conversion sites, and other yards operate in the Jurong area. Zone 1 conditions arise inside tanks and pump rooms during repair and coating work.
Not automatically. Tank entry and hot work normally follow per-vessel gas-free and permit procedures set by the yard, and some yards still require certified equipment in certain spaces. The IS-04Z1 has no certificate yet. Ask the yard safety department which rule applies.
More on Singapore Shipyard, and on other places in Singapore.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.