Tropical marine climate
Heat, humidity and salt spray are constant, and monsoon seasons affect sea state and crew changes.
Natuna had about 84,900 inhabitants in 2025, around 80 percent of Malay origin, and Indonesian and local Malay are the main languages, which helps visiting crews working with local contractors. Platforms and FPSOs are Zone 1 environments for process, drilling and maintenance crews. If you are specifying an Ex-proof smartphone for Offshore Indonesia, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Offshore Indonesia: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | Offshore Indonesia: Wellhead and production platforms, FPSOs and floating production units, Drilling and workover areas | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Offshore Indonesia. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
Heat, humidity and salt spray are constant, and monsoon seasons affect sea state and crew changes.
Personnel and spares move by helicopter and supply vessel, so a failed device may take days to replace.
Natuna Regency, the northernmost part of Riau Islands Province, has only 1,984 sq km of land within a total area of about 264,198 sq km, so almost all of it is open sea.
The Tangguh field in Bintuni Bay, West Papua, was estimated to hold 4.4 trillion cubic feet of proven gas, with annual LNG output expected to reach about 7.6 million tonnes.
Indonesia produced about 450.8 million tonnes of oil equivalent of energy in 2019, and its total primary energy supply rose by nearly 60 percent between 2000 and 2021.
The Arun field in Aceh produced gas from the 1970s and is now largely depleted, and nearby operations included the North Sumatra offshore gas field, with assets passing to Pertamina in 2015.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In Offshore Indonesia. A marking check offshore would match the label to the zone of a wellhead, drilling area or processing module, with the right gas group and temperature class. Gas streams may include hydrogen-bearing components, so reviewers read the drawings. The target marking is II 2 G Ex ib IIC T4, unapproved.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
Likely candidates are wellhead and production platforms, fpsos and floating production units, drilling and workover areas, gas processing modules. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Usually yes for classified areas. Operators normally require equipment certified for the zone, gas group and temperature class of the location, supported by a permit to work. Confirm the exact certification marks the platform accepts for portable devices.
Indonesian is the national language and Malay is widely spoken in areas such as Natuna, while operators typically run safety briefings in English as well. Check that device interfaces and any emergency procedures can be used in the languages your crew needs.
Heat, humidity and salt spray are constant, and monsoon seasons affect sea state and crew changes. Check seals, ports and charging contacts for corrosion. IP68 is useful but is not explosion protection. Confirm approved devices with the operator.
Related guides for Offshore Indonesia and for Indonesia.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.