Remote logistics
Personnel and spares move by helicopter and supply vessel, so a failed device may take days to replace.
Indonesia's offshore oil and gas is spread across the Natuna area, the Java Sea and the Kutai Basin off East Kalimantan, where the Mahakam block is run by Pertamina Hulu Mahakam. Platforms and FPSOs are Zone 1 environments for process, drilling and maintenance crews. If you are specifying an industrial mobile phone for Offshore Indonesia, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Offshore Indonesia: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ingress protection | IP rating for dust and water | IP68 design |
| Fleet management | EMM and MDM support | Android 16 with EMM and MDM |
| Explosion protection | A separate certificate and marking | In progress; not issued |
| Where it applies | Offshore Indonesia: Wellhead and production platforms, FPSOs and floating production units, Drilling and workover areas | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Offshore Indonesia. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
Personnel and spares move by helicopter and supply vessel, so a failed device may take days to replace.
Offshore units for fields such as Belanak in the Natuna Sea have been fabricated at yards in Batam before sailing out.
The Arun field in Aceh produced gas from the 1970s and is now largely depleted, and nearby operations included the North Sumatra offshore gas field, with assets passing to Pertamina in 2015.
The Abadi design uses a gas FPSO that treats the gas before sending it by subsea pipeline to an onshore LNG plant with two trains, and captured CO2 is to be reinjected into the well.
Ranai Airport is among the regency's main transport points, so crew changes and urgent spares for offshore gas work would typically move by air and then by supply boat; confirm routes with the operator.
INPEX operates the offshore Masela block's Abadi gas project with 65%, alongside Pertamina at 20% and Petronas at 15%, targeting about 9.5 million tonnes of LNG a year and up to 35,000 barrels of condensate a day.
“Industrial” describes a phone built for plant conditions: sealed, drop-resistant and manageable at fleet scale through Android Enterprise. It does not by itself mean the phone may enter a classified area. Only a device with a valid explosion-protection certificate and marking may do that.
The IS-04Z1 is designed to be both an industrial Android phone (IP68, 4,000 mAh battery, 50 MP camera, Android 16 with EMM and MDM support) and an intrinsically safe one. Its explosion-protection certificates are in progress and have not been issued.
In Offshore Indonesia. Personnel and spares move by helicopter and supply vessel, so a failed device may take days to replace. Fleets need MDM or EMM enrolment done onshore, spare units in each crew's kit and charging only in safe areas. Connectivity offshore may be limited.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
Yes by design: IP68 sealing, a 4,000 mAh battery, a 50 MP camera and Android 16 with EMM and MDM support. The explosion-protection certificates are separate and still in progress.
Likely candidates are wellhead and production platforms, fpsos and floating production units, drilling and workover areas, gas processing modules. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Usually yes for classified areas. Operators normally require equipment certified for the zone, gas group and temperature class of the location, supported by a permit to work. Confirm the exact certification marks the platform accepts for portable devices.
Indonesian is the national language and Malay is widely spoken in areas such as Natuna, while operators typically run safety briefings in English as well. Check that device interfaces and any emergency procedures can be used in the languages your crew needs.
Heat, humidity and salt spray are constant, and monsoon seasons affect sea state and crew changes. Check seals, ports and charging contacts for corrosion. IP68 is useful but is not explosion protection. Confirm approved devices with the operator.
More on Offshore Indonesia, and on other places in Indonesia.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.