Singapore's major shipyards are run by Seatrium, with yards at Admiralty, Benoi, Pioneer, Tuas and Tuas Boulevard, and by ST Engineering. Repair, conversion and newbuild work brings Zone 1 conditions into tanks, cargo spaces and paint areas. This page explains what to look for in an ATEX and IECEx smartphone for Singapore shipyards, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Singapore Shipyard, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceSmartphone
RouteSpecification
WhereSingapore Shipyard

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Singapore shipyards: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx smartphone for Singapore shipyards

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesSingapore shipyards: Vessel tank spaces, Dry dock and repair work, Paint and coating shopsClassified by the site operator
Product · Singapore Shipyard

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Singapore Shipyard. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Singapore shipyards

Singapore shipyards: where the IS-04Z1 would work

Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.

Operators and companies on site

  • Seatrium
  • ST Engineering

Classified areas to expect

  • Vessel tank spaces
  • Dry dock and repair work
  • Paint and coating shops
  • Offshore conversion
Local conditions · Singapore shipyards

What Singapore shipyards means for portable equipment

Merger

Sembcorp Marine and Keppel Offshore & Marine combined as Seatrium in 2023.

Seatrium sites

Its official contact page lists Admiralty Yard, Benoi Yard, Pioneer Yard, Tuas Yard and Tuas Boulevard Yard in Singapore.

Field notes · Singapore shipyards

More about Singapore shipyards that matters for portable equipment

Singapore shipyards: climate and equipment wear

Heat, humidity and frequent heavy showers affect work on open decks, quays and docks all year round.

Singapore shipyards: projects and investment

Seatrium's repair and upgrade work covers LNG and LPG carriers, cruise ships, ferries, floating production vessels, jack-ups, tankers, container ships and heavy-lift vessels.

Singapore shipyards: infrastructure

The Tuas Boulevard Yard has a graving dock about 350 metres long and 66 metres wide, suited to the largest tankers and floating production units.

Singapore shipyards: background

In 2002 Keppel Shipyard was combined with Keppel FELS and Keppel Singmarine to form the Keppel Offshore and Marine group, which became part of Seatrium in 2023.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In Singapore shipyards. Vessel owners, class surveyors and yard crews from many countries meet in Singapore's yards, so a reviewer would expect ATEX and IECEx evidence for handhelds entering tanks. The IS-04Z1 certification is in progress and only a datasheet is available now. Each yard safety department decides which certificates and conditions it accepts.

The route · specification

Specifying an ATEX and IECEx smartphone for Singapore Shipyard

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Singapore Shipyard

Frequently asked questions

Can we buy an ATEX and IECEx smartphone in Singapore Shipyard today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an ATEX and IECEx smartphone in Singapore Shipyard cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

Which areas at Singapore shipyards would use it?

Likely candidates are vessel tank spaces, dry dock and repair work, paint and coating shops, offshore conversion. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Do large docks create special conditions?

Large graving docks hold very big vessels and many contractors at once, so crowding, crane lifts and hot work overlap. Hazardous-area controls are managed per vessel by the yard's safety team and the owner's representative.

Which Singapore shipyards are major sites for Zone 1 work?

Seatrium's yards at Admiralty, Benoi, Pioneer, Tuas and Tuas Boulevard are the large repair and conversion sites, and other yards operate in the Jurong area. Zone 1 conditions arise inside tanks and pump rooms during repair and coating work.

Do gas-free procedures replace the need for certified equipment?

Not automatically. Tank entry and hot work normally follow per-vessel gas-free and permit procedures set by the yard, and some yards still require certified equipment in certain spaces. The IS-04Z1 has no certificate yet. Ask the yard safety department which rule applies.

Enquiry · Singapore shipyards

Ask about the IS-04Z1 for Singapore shipyards, Singapore

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Singapore shipyards

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Singapore Shipyard?

Name the site and the operator and we will send what is available before launch.