A gas group that includes hydrogen
The target marking is II 2 G Ex ib IIC T4. Group IIC covers hydrogen as well as the hydrocarbons in the tank farm, so one handset can be considered across both fence lines, subject to the zone drawing for each.
An explosion proof mobile phone for refining and Power-to-X in Denmark mostly means Fredericia, where the former Shell refinery now run by Crossbridge Energy supplies roughly a third of Danish liquid fuel and a hydrogen electrolysis project has been built on the same industrial harbour. Fuel terminals at Stigsnæs and on the Copenhagen waterfront add storage and loading areas. The IS-04Z1 is designed around intrinsic safety rather than a flameproof enclosure.
Launching Q4 2026 · ATEX programme in progress
The Fredericia refinery opened in 1966 as a Shell site, and Crossbridge Energy Partners took it over effective 1 July 2021. Crossbridge says it produces around 35 per cent of Danish liquid fuel consumption and exports a similar amount through its own port terminal. That is a continuous process site: crude distillation and conversion units, product tankage, and loading at the quay and the road and rail racks. Next to it is HySynergy, Everfuel’s electrolysis project, whose first 20 MW phase is reported to be operating, with expansion to 300 MW planned. Hydrogen is a gas group IIC substance, the most demanding group, so the area classification around the electrolysers and the pipework to the refinery is a separate exercise from the hydrocarbon units. Beyond Fredericia, fuel terminals at Prøvestenen in Copenhagen and at Stigsnæs on Zealand handle bunker and product storage.
Fredericia combines a conventional hydrocarbon site, a harbour and a hydrogen project on neighbouring land. These are the points that matter for a device.
The target marking is II 2 G Ex ib IIC T4. Group IIC covers hydrogen as well as the hydrocarbons in the tank farm, so one handset can be considered across both fence lines, subject to the zone drawing for each.
Fredericia sits on the Little Belt, with wind and spray on the quays. IP68 sealing is aimed at that kind of exposure, with the proviso that a trial should include a full shift outdoors.
A turnaround fills the site with contractors for a few weeks. Android 16 with Android Enterprise and MDM lets a site enrol, restrict and later wipe a large batch of devices from its existing console.
The 50 MP camera produces a legible record of a blind, a valve position or a gauge, and your own console decides where those images are stored.
The 4,000 mAh battery is specified for a shift, which matters when the walk between the tank farm and the quay is long and there is no charging point inside the classified boundary.
Contractor crews carry the job pack, the isolation photograph and the sign-off on a managed handset, instead of a paper folder that leaves with the contractor when the turnaround ends.
An operator walking a route at a product terminal records readings, photographs a defect and calls the control room from the tank farm, without a detour to the safe area.
A hydrogen plant has its own zone drawing, its own contractors and a stream of visitors. An enrolled handset with a defined set of applications keeps their device policy tight from the first day on the site.
The refinery runs continuously and is stopped on a planned cycle, while the electrolysis project and the terminals have their own staffing and contractors.
At Fredericia, ordinary shifts are run by the operator’s own staff, and the big increases in people come with turnarounds, when specialist contractors arrive for fixed windows. Crossbridge and Everfuel are separate companies, and the sites are adjacent rather than joined. So the first question for a supplier is which fence line a device is meant for, and which company’s procurement and HSE teams will approve it.
Danish equipment rules are those of the EU: ATEX for the product, the employer’s duty to assess explosion risk and hold an explosion protection document under Arbejdstilsynet, and zones set by Beredskabsstyrelsen. We have no verified detail of any company’s supplier registration, so ask the operator’s procurement and HSE teams what they require of a communications device, including whether they expect an Achilles JQS profile, and what evidence they want from a supplier whose certificates are still being issued.
No. It is pre-launch, and ATEX, IECEx and NEC 500 certification are in progress ahead of the Q4 2026 launch. Nothing is supplied into a classified area before the certificate covering it exists.
Hydrogen is gas group IIC, which is the group the target marking covers, so the group itself is not the obstacle. The zone drawing and temperature class for each area are what must be matched, and the electrolysis plant has its own.
No. Crossbridge and Everfuel are separate companies, each with its own procurement and HSE approval, even though the sites are next to each other.
The page is about Fredericia and the fuel terminals at Prøvestenen and Stigsnæs. Storage sites with bulk liquids share many of the same vapour hazards, but classification is site specific and comes from each operator’s drawing.
Tell us the site, the zone and gas group, and roughly how many handsets. The SAMS team replies by email with the datasheet and the certification schedule for Denmark. The IS-04Z1 is pre-launch and certification is in progress, so there is no list price yet; indicative pricing is issued in writing against a stated quantity and site.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule for your market.