Scale
JTC and EDB describe Jurong Island as a hub for refining, olefins production and chemical manufacturing, with over 100 global companies.
Singapore's petrochemical sector is concentrated on Jurong Island, a roughly 3,000-hectare park with over 100 companies, and on Pulau Bukom. Refining, olefins and chemical plants, tank farms and polymer handling create Zone 1 and Zone 21 areas. Distribution partners for Singapore petrochemical sector are being identified ahead of the Q4 2026 launch of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. Singapore petrochemical sector has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ingress protection | IP65 to IP68 sealing | IP68 design |
| Drop and shock | A stated drop height onto concrete | Specification on request |
| Explosion protection | A separate certificate and marking | In progress; not issued |
| Where it applies | Singapore petrochemical sector: Tank farms, Polymer handling and dust areas, Cracker process units | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Singapore Petrochemical. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
A short profile of the site and the kinds of classified area that matter for portable equipment.
JTC and EDB describe Jurong Island as a hub for refining, olefins production and chemical manufacturing, with over 100 global companies.
ExxonMobil states that its 592,000-barrel-per-day Singapore refinery is fully integrated with its Singapore Chemical Plant.
Major Hazard Installations in Singapore need documented hazardous area classification drawings under the Workplace Safety and Health framework overseen by MOM and SCDF.
Pulau Bukom has hosted Singapore's refining industry since 1961, when it became the site of the nation's first oil refinery.
Natural gas is the main fuel for Singapore's power generation, and the LNG terminal on Jurong Island can supply about 9 million tonnes a year on average to power and industry.
Energy and chemicals is Singapore's second-largest manufacturing sector, with more than 100 global chemicals companies, and the country is positioned as a hub for petrochemical production and trading.
A rugged phone is built to survive water, dust, drops and rough handling, usually rated by an IP code and a drop specification. Ruggedness is an environmental property: it says nothing about whether a phone may be used where flammable gas or dust is present. That is decided by explosion-protection certification and marking.
The IS-04Z1 combines both: an IP68 sealed rugged build and a design for Zone 1 and Zone 21 (marking target Ex ib IIC T4). The explosion-protection certificates are in progress and none has been issued.
In Singapore petrochemical sector. Jurong Island is hot and humid and exposed to sea air, and polymer plants add fine dust. IP68 dust and water protection is designed in for the IS-04Z1 and helps in those conditions. It is not explosion protection, which depends on the Ex certification that is in progress.
SAMS is appointing authorised distributors ahead of the Q4 2026 launch. No territory has been granted for Singapore petrochemical sector yet and applications are reviewed company by company. Because a certified Ex device cannot be opened by an ordinary phone workshop without invalidating its certificate, SAMS looks for partners who can provide competent technical support and after-sales service locally.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
It is designed to IP68 sealing, with glove-friendly controls. Ruggedness is not explosion protection: that depends on the certificates, which are in progress.
Likely candidates are cracker process units, chemical derivative plants, tank farms, polymer handling and dust areas. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for Singapore petrochemical sector.
Plant operators set the detailed rules, within workplace safety duties enforced by MOM and flammable-material duties under SCDF. Many require pre-approval of electronic devices, so provide model, certificate and zone details before the visit.
Turnarounds bring many contractors and tight schedules, and devices should be approved well before they begin. Dates are set by each operator, so ask the site's turnaround planner for the calendar and the equipment-approval lead time.
The target marking, II 2 G Ex ib IIC T4, is a gas marking. Polymer handling and dust areas are described as Zone 21, which is a dust classification and needs a separate dust-rated marking. The device has no certificate yet. Ask the plant which areas apply.
More on Singapore Petrochemical, and on other places in Singapore.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Name the site and the operator and we will send what is available before launch.