Ports
The city has two seaports, the Jubail Commercial Seaport and the King Fahd Industrial Seaport.
Jubail Industrial City covers just over 1,000 square kilometres on the Gulf coast of the Eastern Province and is managed by the Royal Commission for Jubail and Yanbu, established in 1975. It houses SABIC plants, the SATORP and SASREF refineries and the Sadara chemical complex, so classified areas are widespread. This page explains what to look for in an industrial mobile phone for Jubail Industrial City, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Jubail Industrial City: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ingress protection | IP rating for dust and water | IP68 design |
| Fleet management | EMM and MDM support | Android 16 with EMM and MDM |
| Explosion protection | A separate certificate and marking | In progress; not issued |
| Where it applies | Jubail Industrial City: Utilities and gas processing, Refinery process units, Petrochemical and chemical plants | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Jubail. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The companies on site and the hazardous-area types a handset is likely to meet there.
The city has two seaports, the Jubail Commercial Seaport and the King Fahd Industrial Seaport.
Hot desert climate with summer temperatures that can exceed 50 C.
The Royal Commission's chairman's office is in Riyadh, with separate directorates general in Jubail and Yanbu, so city-level services are run locally while plants set their own rules.
The city hosts what is described as the world's largest independent water and power project, producing about 2,743.6 MW of electricity and 800,000 cubic metres of water a day.
Associated gas from oil extraction is collected and processed by Aramco and piped to Jubail and Yanbu as petrochemical feedstock, so gas-handling and pipeline areas feed the plants.
Dammam's airport terminal is about 60 km by road from the Jubail suburbs, 80 km from the city centre and 100 km from the Royal Commission neighbourhoods.
“Industrial” describes a phone built for plant conditions: sealed, drop-resistant and manageable at fleet scale through Android Enterprise. It does not by itself mean the phone may enter a classified area. Only a device with a valid explosion-protection certificate and marking may do that.
The IS-04Z1 is designed to be both an industrial Android phone (IP68, 4,000 mAh battery, 50 MP camera, Android 16 with EMM and MDM support) and an intrinsically safe one. Its explosion-protection certificates are in progress and have not been issued.
In Jubail Industrial City. The Royal Commission for Jubail and Yanbu runs the industrial city, but each plant operator sets its own contractor rules. A contractor working on several plants may need devices enrolled differently for each client. The IS-04Z1 runs Android 16 and is designed for EMM and MDM, and charging belongs in a safe area.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
Yes by design: IP68 sealing, a 4,000 mAh battery, a 50 MP camera and Android 16 with EMM and MDM support. The explosion-protection certificates are separate and still in progress.
Likely candidates are refinery process units, petrochemical and chemical plants, storage and loading terminals, port bulk handling. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Many. The Royal Commission plans and runs the industrial city, but chemical, refining, power and port companies operate their own plants under their own safety and permit rules. Equipment approval for handheld devices is usually decided plant by plant.
Gas-fired power and desalination plants usually include fuel-gas supply areas, so some classified zones are likely. The city's independent water and power project is among the largest in the world, so contractor numbers are high; confirm requirements with the specific plant.
Not automatically. Each plant operator sets its own approved-vendor and permit rules, so approval at one plant does not guarantee acceptance at another. Confirm current requirements with the operator or its contractor for each plant. This applies on top of explosion-protection certification.
More on Jubail, and on other places in Saudi Arabia.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.