Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Dumai Refinery · IECEx

IECEx Mobile Phone in Dumai Refinery

All six of Indonesia's oil refineries are run by Pertamina, and together they supplied only about half of national fuel demand, which is why upgrade programmes cover the largest units including Dumai. Crude processing, storage and marine loading create Zone 1 areas. This page explains what to look for in an IECEx mobile phone for Dumai Refinery, Riau, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Dumai Refinery, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicIECEx
DeviceMobile Phone
RouteSpecification
WhereDumai Refinery

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Dumai Refinery, Riau: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.

At a glance · IECEx

Checklist: IECEx mobile phone for Dumai Refinery, Riau

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
Certificate of conformityNumber checkable on the IECEx online registerIn progress; not issued
Standards editionThe IEC 60079 edition the certificate citesStated on the certificate when issued
Schedule of conditionsLimits of use, batteries and accessoriesPublished with the certificate
Where it appliesDumai Refinery, Riau: Refinery process units, Crude and product tank farms, Marine loading jettiesClassified by the site operator
Product · Dumai Refinery

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Dumai Refinery. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Dumai Refinery, Riau

Working in Dumai Refinery, Riau: operators and classified areas

The companies on site and the hazardous-area types a handset is likely to meet there.

Operators and companies on site

  • Pertamina

Classified areas to expect

  • Refinery process units
  • Crude and product tank farms
  • Marine loading jetties
Local conditions · Dumai Refinery, Riau

What Dumai Refinery, Riau means for portable equipment

Climate

Hot, humid equatorial conditions with rain through the year.

Two sites

Fortune Indonesia reports the unit has been operating since 1971 and spans Dumai and Sungai Pakning, with products including LPG, jet fuel, diesel and green coke.

Field notes · Dumai Refinery, Riau

More about Dumai Refinery, Riau that matters for portable equipment

Dumai Refinery, Riau: logistics and access

Dumai lies about 188 km from Pekanbaru and is connected to the Trans-Sumatra Highway and toll road; Pinang Kampai Airport has daily domestic flights to Jakarta, Pekanbaru, Medan and Batam.

Dumai Refinery, Riau: background

The Dumai refinery has operated since 1971, and the Putri Tujuh Dumai and Sungai Pakning refineries together have supplied fuel to Sumatra and contributed to regional development in Riau.

Dumai Refinery, Riau: infrastructure

The refinery generates the power it needs from natural gas supplied by fields in South Sumatra and Jambi, including Grissik, Bentu and Jambi Merang, which cuts its fuel cost by about 40 percent.

Dumai Refinery, Riau: geography and layout

Dumai is on the coast of Riau Province in Sumatra and supplies the island with gasoline, aviation fuel, diesel, kerosene and LPG, so it is a regional distribution hub as well as a processing site.

The term · IECEx

What “IECEx” means for a smartphone

IECEx is the international scheme for certifying equipment used in explosive atmospheres. A certificate of conformity is issued by an accredited certification body against a specific edition of the IEC 60079 standards and carries a schedule of conditions of safe use. It is not a legal requirement in most countries on its own, but many national schemes accept it as the technical basis.

The IECEx certificate for the IS-04Z1 is in progress and has not been issued. The marking target is Ex ib IIC T4, the intrinsic safety concept for Zone 1 gas with the hardest gas group (IIC) and a 135 °C temperature class.

In Dumai Refinery, Riau. The IECEx scheme gives visiting contractors a familiar reference when they move between Dumai, Sungai Pakning and other refineries. A certificate of conformity plus schedule of conditions would be reviewed. For the IS-04Z1 those documents are targets, not issued.

The route · specification

Specifying an IECEx mobile phone for Dumai Refinery

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Dumai Refinery

Frequently asked questions

Can we buy an IECEx mobile phone in Dumai Refinery today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an IECEx mobile phone in Dumai Refinery cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

Does the IS-04Z1 hold an IECEx certificate?

No. The IECEx certificate is in progress and has not been issued. SAMS will publish the number when it exists.

Which areas at Dumai Refinery, Riau would use it?

Likely candidates are refinery process units, crude and product tank farms, marine loading jetties. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Does green coke at Dumai create a dust hazard for electronics?

Green coke is a petroleum-coke product, and fine carbon dust can be combustible and conductive. Where it is handled, sites may classify combustible-dust zones, so ask the operator whether your handset needs a dust-rated device and how often it must be cleaned.

Is Dumai reachable for equipment shipments?

Dumai is a coastal port city in Riau Province, so sea freight is practical, and many visitors fly to Pekanbaru and continue by road. Plan for customs clearance in Indonesia and a site gate check, and confirm lead times with your freight agent.

Is Dumai's humidity a problem for a handset?

Equatorial heat and rain through the year affect battery performance and seals, so check the rated operating range and charging arrangements. Charge only in safe areas. Rain protection does not equal explosion protection. Confirm the permitted device list with the operator.

Enquiry · Dumai Refinery, Riau

Ask about the IS-04Z1 for Dumai Refinery, Riau, Indonesia

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · Dumai Refinery, Riau

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Dumai Refinery?

Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.