DSEAR duties fall on employers and the self-employed and also protect members of the public who may be put at risk by work activity, so contractors share responsibility with site owners. Lindsey stopped refining in 2025. Distribution partners for England are being identified ahead of the Q4 2026 launch of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for England, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topichazardous area
DeviceSmartphone
RouteDistribution
WhereEngland

Short answer. England has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.

At a glance · hazardous area

Checklist: hazardous area smartphone for England

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
Zone0, 1 or 2 for gas; 20, 21 or 22 for dustDesigned for Zone 1 and Zone 21
Gas groupIIA, IIB or IICIIC (target)
Area drawingThe operator's own classification drawingDecided by the site operator
Where it appliesEngland: Marine oil jetties, Petrochemical units, Refinery process unitsClassified by the site operator
Product · England

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in England. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · England

England: where the IS-04Z1 would work

Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.

Operators and companies on site

  • ExxonMobil
  • EET Fuels (Essar)
  • Phillips 66

Classified areas to expect

  • Refinery process units
  • Fuel terminals and tank farms
  • Marine oil jetties
  • Petrochemical units
Local conditions · England

What England means for portable equipment

Regulation

DSEAR applies, and the UK recognises CE marking alongside UKCA for Great Britain, with the recognition period currently running to 31 December 2027.

Operating refineries

Reported capacities are roughly 270,000 barrels a day at ExxonMobil's Fawley on Southampton Water, about 296,000 at Stanlow in Cheshire and about 221,000 at Phillips 66's Humber site in North Lincolnshire.

Field notes · England

More about England that matters for portable equipment

England: rules and approvals

Employers must identify and classify areas where explosive atmospheres may occur and avoid ignition sources, for example from unprotected equipment, in those areas.

England: industry on the ground

HSE lists dangerous substances as including solvents, paints, varnishes, flammable gases such as LPG, dusts from machining, sanding and foodstuffs, pressurised gases and substances corrosive to metal.

England: rules and approvals

In Great Britain, the 2016 EPS Regulations implement the ATEX equipment directive, and the UK government has extended recognition of goods meeting EU requirements, including CE marking, indefinitely beyond 2024 for many products, in force from 1 October 2024.

England: rules and approvals

The Dangerous Substances and Explosive Atmospheres Regulations 2002, known as DSEAR, require employers to control risks to safety from fire, explosion and substances corrosive to metals in the workplace.

The term · hazardous area

What “hazardous area” means for a smartphone

A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.

No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.

In England. England's classified areas include refinery process units, fuel terminals and tank farms, marine oil jetties and petrochemical units. The employer classifies them under DSEAR, not SAMS. Lindsey stopped refining in 2025, so its activity differs from the three operating English refineries, and terminals and gas networks add smaller classified areas elsewhere.

The route · distribution

Distributing the IS-04Z1 in England

A distributor for England would carry the IS-04Z1 after certification completes; the Q4 2026 launch is the planning date and no appointment has been made. SAMS reviews applicants one by one and prefers companies with their own Ex-competent technical and service staff, since certified devices must not be repaired outside approved channels.

What SAMS looks for in a partner

Operator relationships
Existing supplier registrations or a clear route to them with the main operators and contractors in England.
Ex-competent staff
People who understand zone classification, markings and the conditions of a certificate.

And equally important

Local-language support
Documentation, training and helpdesk in the languages the workforce uses.
Service capability
Spares, battery replacement and repair routed through SAMS-approved channels.
Questions · England

Frequently asked questions

Can we buy a hazardous area smartphone in England today?

Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.

What does a hazardous area smartphone in England cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

Which hazardous areas is the IS-04Z1 designed for?

Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.

Which areas at England would use it?

Likely candidates are refinery process units, fuel terminals and tank farms, marine oil jetties, petrochemical units. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

How do I become a SAMS distributor for England?

Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for England.

Does COMAH affect which equipment I can use?

COMAH applies to major-hazard sites such as large chemical and fuel storage establishments and adds management duties on top of DSEAR. Each operator typically sets its own rules for portable electronics, so check the site's permit and induction requirements.

Which regulations govern portable electronics in explosive atmospheres in England?

The Dangerous Substances and Explosive Atmospheres Regulations 2002 require employers to classify hazardous areas and avoid ignition sources. Equipment choice is then based on the zone, gas group and temperature class, so ask the site for its hazardous-area register.

Does the UK accept CE marking or only UKCA?

Guidance says CE marking is recognised alongside UKCA for Great Britain, with the recognition period currently running to 31 December 2027, and that date may change. Buyers should check the current gov.uk guidance and ask their operator's procurement team what evidence they require.

Enquiry · England

Ask about the IS-04Z1 for England, United Kingdom

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · England

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for England?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.