SOHAR Port is described as handling more than one million tonnes of sea cargo a week and around 3,500 ship calls a year, so jetty and yard traffic is continuous. Refining, metals and iron-ore processing are clustered there, which creates Zone 1 and Zone 21 work in process plants and bulk-liquid storage. This page explains what to look for in an Ex-proof smartphone for Sohar, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Sohar, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicEx-proof
DeviceSmartphone
RouteSpecification
WhereSohar

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Sohar: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.

At a glance · Ex-proof

Checklist: Ex-proof smartphone for Sohar

Checks a reviewer should make, with the IS-04Z1 position
CheckWhat to look forIS-04Z1 today
Ex markingGroup, category, protection concept, gas group, temperature classII 2 G Ex ib IIC T4 (target)
Gas groupIIA, IIB or IIC matched to the area drawingIIC (target)
Temperature classT-class below the ignition temperature of the gasT4, 135 °C (target)
Where it appliesSohar: Refinery process units, Port liquid bulk handling, Fuel and chemical storageClassified by the site operator
Product · Sohar

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Sohar. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Sohar

Sohar: where the IS-04Z1 would work

Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.

Operators and companies on site

  • Sohar Industrial Port Company (50:50 joint venture of the Port of Rotterdam and Oman)
  • OQ (Sohar refinery)
  • Sohar Aluminium
  • Vale Oman

Classified areas to expect

  • Refinery process units
  • Port liquid bulk handling
  • Fuel and chemical storage
  • Industrial plant utilities
Local conditions · Sohar

Site conditions at Sohar: what wears and what limits equipment

Large industrial base

The Sohar Aluminium smelter has a capacity of roughly 390,000 tonnes a year with its own power plant, so construction and maintenance contractors are present.

Hot climate

Summers are very hot on this stretch of the Gulf of Oman coast, so handset heat tolerance matters for outdoor rounds.

Field notes · Sohar

More about Sohar that matters for portable equipment

Sohar: rules and approvals

Oman's Telecommunications Regulatory Authority follows EU-style type-approval procedures for radio equipment and issues a TRA label; a self-declaration route has also been introduced, so confirm the current path.

Sohar: climate and equipment wear

Sohar has a hot desert climate with very hot summers and mild winters; rain is scarce, with more than half the annual total falling in February, so summer heat is the main stress.

Sohar: industry on the ground

The port and free zone were planned around three industrial clusters, logistics, metals and petrochemicals, and a food cluster with an agro-bulk terminal was added later, giving mixed gas and dust hazards.

Sohar: geography and layout

The port lies in Liwa wilaya, in the centre of Al Batinah North Governorate, on the Gulf of Oman side of the Strait of Hormuz, so ships reach it without passing through the strait.

The term · Ex-proof

What “Ex-proof” means for a smartphone

“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.

The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.

In Sohar. For a refinery unit, port liquid bulk berth or fuel and chemical storage, a marking check reads zone, gas group and temperature class on the label and compares each with the operator's records. Fuels and chemicals span several gas groups, so the target marking II 2 G Ex ib IIC T4 is compared with the site data.

The route · specification

Specifying an Ex-proof smartphone for Sohar

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Sohar

Frequently asked questions

Can we buy an Ex-proof smartphone in Sohar today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an Ex-proof smartphone in Sohar cost?

There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.

What Ex marking will the IS-04Z1 carry?

The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.

Which areas at Sohar would use it?

Likely candidates are refinery process units, port liquid bulk handling, fuel and chemical storage, industrial plant utilities. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Does heat at Sohar affect handset choice for outdoor rounds?

Summers are very hot there, so check the datasheet operating and charging temperature range, keep devices out of direct sun on jetties, and plan battery swaps for long shifts. Ask the plant operator whether it sets its own temperature limit for portable devices.

Can UAE-based service teams reach Sohar easily?

Sohar has road links towards the UAE, and the Hafeet Rail corridor is being built to join the port to the UAE network. For hazardous areas, border and site-access paperwork still sits with the client, so allow time for permits and inductions.

Do I need separate approvals for each Sohar operator?

Each operator at the port runs its own supplier approval and permit system, so one approval does not cover all. Ask the refinery, port company or industrial plant what it requires for portable devices. Confirm with the operator.

Enquiry · Sohar

Ask about the IS-04Z1 for Sohar, Oman

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Sohar

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Sohar?

Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.