Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Hungary · ATEX and IECEx

ATEX and IECEx Smartphone Supplier in Hungary

The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, built for Hungarian refinery units, polymer plants, pharmaceutical solvent areas and gas installations. Buyers searching for an ATEX and IECEx smartphone supplier for Hungary can take the datasheet and the certification schedule for the IS-04Z1 now; supply follows certification.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Hungary, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceSmartphone
RouteSupply
WhereHungary

Short answer. An ATEX and IECEx smartphone for Hungary cannot be bought yet: the SAMS IS-04Z1 is pre-launch (certification in progress, no certificate issued), and the datasheet, certification schedule and safe-area evaluation units are available now.

Current position: certification in progress, nothing issued, launch targeted for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx smartphone for Hungary

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesHungary: Budapest, Algyő, SzázhalombattaClassified by the site operator
Product · Hungary

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Hungary. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Hungary

Where this applies in Hungary

The classified areas, operators and sites below are the ones covered in the SAMS Hungary market guide.

Operators, EPCs and contractors

MOL
Danube Refinery at Százhalombatta and the domestic upstream fields.
MOL Petrolkémia
Cracker, polymer plants and the polyol complex at Tiszaújváros.
BorsodChem
MDI, TDI and PVC production at Kazincbarcika.
Richter Gedeon
Pharmaceutical production and solvent handling in Budapest and Dorog.
Egis
Pharmaceutical manufacturing and solvent recovery in Budapest and Körmend.
FGSZ
Natural gas transmission system operator and its compressor stations.

Industrial areas and sites

Százhalombatta
Danube Refinery and the units and tank farm around it.
Tiszaújváros
Steam cracker, polyolefin plants and the polyol complex.
Kazincbarcika
Isocyanate, chlorine and PVC production on one site.
Dorog
Pharmaceutical and fine chemical production with solvent areas.
Budapest
Pharmaceutical plants, laboratories and fuel storage on the city edge.
Algyő
Historic oil and gas field and gathering facilities near Szeged.
Field notes · Hungary

More about Hungary that matters for portable equipment

Hungary: infrastructure

Four operating reactors built between 1982 and 1987 form the Paks Nuclear Power Plant, and nuclear is the main domestic energy source, with almost half of Hungary's energy imported as of 2024.

Hungary: who works there

MOL is active in exploration and production, refining, distribution, petrochemicals, power generation, trading and retail, with operations in over 30 countries and 2,400 service stations in ten countries as of 2025.

Hungary: industry on the ground

MOL's Danube Refinery at Százhalombatta started up in 1965 and has a capacity of about 8.1 million tonnes a year, making it one of the largest refineries in Central and Eastern Europe.

Hungary: industry on the ground

The Matra power plant, the last coal electricity producer, supplied about 9% of Hungary's electricity in 2020 and was served by coal mines in Visonta and Bükkábrány, with a gas combined-cycle replacement planned.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In Hungary. A Hungarian reviewer at MOL, Tiszaújváros or a pharmaceutical plant would expect ATEX evidence consistent with the EU directive and the national decree that implements it. IECEx papers help international EPCs and contractors working across several countries. A dual route lets one pack serve both audiences. Certification is in progress; no certificate has been issued.

The route · supply

Sourcing the IS-04Z1 for Hungary

Nothing can be bought for Hungary today: the IS-04Z1 is pre-launch, and SAMS will supply end users through authorised distributors once certificates exist. What a buyer can do now is take the specification, ask for the written certification schedule and arrange a safe-area evaluation, so that the right local channel contacts you at launch.

  1. 01

    Request the datasheet

    The technical specification, marking target and conditions of use, sent by email.

  2. 02

    Ask for the certification schedule

    Which certificates are in progress, in what order, and what is still to be confirmed.

  3. 03

    Evaluate in a safe area

    Evaluation units can be used for connectivity, MDM enrolment and workflow testing outside classified areas.

  4. 04

    Register for launch

    Tell us the site, zone, gas group and quantity so the right authorised distributor can contact you.

Questions · Hungary

Frequently asked questions

Can we buy an ATEX and IECEx smartphone in Hungary today?

Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.

What does an ATEX and IECEx smartphone in Hungary cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

Which sites in Hungary does this cover?

The market guide for Hungary covers Százhalombatta, Tiszaújváros, Kazincbarcika, Dorog, among others. Site-level pages are linked below.

How will SAMS supply Hungary?

Through authorised distributors once certificates exist. Until then SAMS can send the datasheet and certification schedule and arrange safe-area evaluation units.

How does Hungary's winter weather affect Ex handheld devices?

Continental winters can bring sub-zero temperatures, which reduce battery capacity. Check the lowest rated ambient temperature on the certificate and whether touch input works with gloves. Plan spare batteries and warm storage for outdoor work at refineries and pipeline stations.

Which Hungarian companies run the main classified-area sites?

MOL is the largest integrated oil, gas and petrochemical group, and the Paks plant and gas network operators also have hazardous areas. Each company runs its own supplier approval, so contact its procurement and HSE teams for current device and contractor requirements.

Can one device cover both a refinery and a pharmaceutical plant?

Gas groups, dust and temperature needs differ between a refinery and a solvent suite. A device would need a marking that suits each classification. Check each plant's zone documents, since the answer depends on the operator's classification rather than the device alone.

Enquiry · Hungary

Ask about the IS-04Z1 for Hungary

Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.

Enquiry · Hungary

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Hungary?

Name the site and the operator and we will send what is available before launch.