Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Ras Tanura · ATEX and IECEx

ATEX and IECEx Smartphone in Ras Tanura

Ras Tanura is a peninsula governorate in the Eastern Province hosting Aramco's Ras Tanura Refinery, with a crude distillation capacity of 550,000 barrels a day, and one of the world's largest crude export terminals. Refining, terminal and gas plant areas create Zone 1 conditions. If you are specifying an ATEX and IECEx smartphone for Ras Tanura, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Ras Tanura, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceSmartphone
RouteSpecification
WhereRas Tanura

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Ras Tanura: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx smartphone for Ras Tanura

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesRas Tanura: Refinery process units, Crude export terminal piers and sea islands, Storage tank farmsClassified by the site operator
Product · Ras Tanura

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Ras Tanura. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Ras Tanura

Ras Tanura at a glance: who is there, what is classified

A short profile of the site and the kinds of classified area that matter for portable equipment.

Operators and companies on site

  • Saudi Aramco

Classified areas to expect

  • Refinery process units
  • Crude export terminal piers and sea islands
  • Storage tank farms
  • Natural gas liquids fractionation (Ju'aymah)
Local conditions · Ras Tanura

What Ras Tanura means for portable equipment

Terminal

The oil terminal has North and South Piers and a Sea Islands section.

Wider complex

The governorate also has the Ju'aymah gas plant and the Ghazlan power plant serving Eastern Province industry.

Field notes · Ras Tanura

More about Ras Tanura that matters for portable equipment

Ras Tanura: rules and approvals

Saudi Arabia's Communications, Space and Technology Commission handles radio type approval; certificates are renewed every two years, with European test documents accepted.

Ras Tanura: background

The refinery was established in 1939 and expanded substantially after the Second World War, so equipment and layouts range from very old to recently modernised.

Ras Tanura: background

The area was officially called Rahima from 1941 until 1986, when the historical name was restored, so older Aramco documents and maps may use the earlier name.

Ras Tanura: logistics and access

The marine complex is described as handling over 2,000 tankers a year, using an artificial island, north and south piers and the Ju'aymah crude terminal.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In Ras Tanura. Ras Tanura reviewers from Aramco would expect certificate evidence that suits the refinery, terminal and fractionation areas. A dual ATEX and IECEx route helps international contractors and marine specialists who work across terminals in several countries. The IS-04Z1 has no certificate yet; certification is in progress.

The route · specification

Specifying an ATEX and IECEx smartphone for Ras Tanura

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Ras Tanura

Frequently asked questions

Can we buy an ATEX and IECEx smartphone in Ras Tanura today?

Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.

What does an ATEX and IECEx smartphone in Ras Tanura cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

Which areas at Ras Tanura would use it?

Likely candidates are refinery process units, crude export terminal piers and sea islands, storage tank farms, natural gas liquids fractionation (ju'aymah). Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Who sets equipment rules at Ras Tanura?

Saudi Aramco manages and operates the industrial infrastructure, so its safety and approval procedures apply to contractors working on the refinery, terminal and gas plant. Check the current vendor and equipment-approval requirements with the Aramco project owner or the main contractor.

Are Ras Tanura facilities old or new?

Both. The refinery dates from 1939 and has been expanded many times, so older plant sits alongside modern units. For handheld devices, ask for the area classification and equipment group for each unit, since gas groups and temperature classes can differ between old and new areas.

Can a handset be used on the piers and sea islands?

Only if its protection suits the classified area there, and if the operator permits it. The piers and sea islands handle crude, where Aramco classifies the area. Ask Aramco or the site contractor for the zone and the device approval route before any handset goes near a loading point.

Enquiry · Ras Tanura

Ask about the IS-04Z1 for Ras Tanura, Saudi Arabia

Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.

Enquiry · Ras Tanura

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Ras Tanura?

Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.