Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Habshan Gas · ATEX and IECEx

ATEX and IECEx Smartphone in Habshan Gas

Habshan, in south-western Abu Dhabi, is ADNOC Gas's largest processing complex, with five plants and 14 processing trains and 6.1 bscfd capacity. It yields sales gas, NGLs, condensate and sulphur, so Zone 1 areas cover process, compression and storage units. If you are specifying an ATEX and IECEx smartphone for Habshan gas complex, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Habshan Gas, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceSmartphone
RouteSpecification
WhereHabshan Gas

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Habshan gas complex: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx smartphone for Habshan gas complex

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesHabshan gas complex: Gas processing trains, NGL and condensate handling, Sulphur and acid-gas unitsClassified by the site operator
Product · Habshan Gas

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Habshan Gas. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Habshan gas complex

Habshan gas complex: where the IS-04Z1 would work

Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.

Operators and companies on site

  • ADNOC Gas

Classified areas to expect

  • Gas processing trains
  • NGL and condensate handling
  • Sulphur and acid-gas units
  • Gas pipelines
Local conditions · Habshan gas complex

What Habshan gas complex means for portable equipment

Sour gas

Much of the Habshan area is designated Red Zone because of hydrogen sulphide gas, so site-specific safety controls apply.

Pipelines

Two pipelines of over 200 km link Habshan with Das Island, and the Habshan-Fujairah crude pipeline starts here.

Field notes · Habshan gas complex

More about Habshan gas complex that matters for portable equipment

Habshan gas complex: background

Pipeline construction began in March 2008 and finished in March 2011; it became operational in June 2012, so its pump and metering stations are of 2010s vintage.

Habshan gas complex: rules and approvals

UAE handsets need type approval from the Telecommunications and Digital Government Regulatory Authority, which also required advanced mobile location testing for cell phones.

Habshan gas complex: industry on the ground

A large part of the Habshan area is marked as a Red Zone because hydrogen sulphide gas is present, so site entry rules and gas-safety practice are a key planning point for any visit.

Habshan gas complex: infrastructure

The Habshan to Fujairah crude pipeline is 406 km long, has a 48-inch diameter and a capacity of 1.5 million barrels a day.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In Habshan gas complex. Habshan is ADNOC Gas's largest processing complex, so a reviewer would look for certificate numbers, markings and schedules of conditions for devices going into Zone 1 process, compression and storage units. A dual ATEX and IECEx route helps international contractors on turnaround projects. The IS-04Z1 certification is in progress.

The route · specification

Specifying an ATEX and IECEx smartphone for Habshan Gas

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Habshan Gas

Frequently asked questions

Can we buy an ATEX and IECEx smartphone in Habshan Gas today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an ATEX and IECEx smartphone in Habshan Gas cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

Which areas at Habshan gas complex would use it?

Likely candidates are gas processing trains, ngl and condensate handling, sulphur and acid-gas units, gas pipelines. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

How far does the Habshan to Fujairah pipeline run?

About 406 km, with a 48-inch diameter and a capacity of 1.5 million barrels a day, passing east of Abu Dhabi city, through Sweihan and west of Al Ain. Pumping and metering stations along it have their own classified areas, set by the operator.

Do Habshan sites have their own contractor rules?

Yes. As a controlled oil and gas area with worker camps, access is managed by the operator, normally through registered contractors with induction and permit procedures. Confirm current requirements for portable electronic devices and gas detection with the operator's HSE team.

What is the Red Zone at Habshan and does it affect handhelds?

Much of the Habshan area is designated Red Zone because of hydrogen sulphide, so site-specific safety controls apply. These are separate from explosion protection, and are set by ADNOC Gas. Ask the operator what is required for a device and for personnel in those areas.

Enquiry · Habshan gas complex

Ask about the IS-04Z1 for Habshan gas complex, United Arab Emirates

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Habshan gas complex

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Habshan Gas?