Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Bontang LNG · ATEX and IECEx

ATEX and IECEx Mobile Phone in Bontang LNG

Bontang hosts the Badak LNG plant, owned by Pertamina and run by PT Badak NGL. It has eight liquefaction trains with a design capacity of 22.5 million tonnes a year, though only a few are in service. Liquefaction, storage and loading create Zone 1 areas. If you are specifying an ATEX and IECEx mobile phone for Bontang LNG (Badak LNG), East Kalimantan, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Bontang LNG, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceMobile Phone
RouteSpecification
WhereBontang LNG

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Bontang LNG (Badak LNG), East Kalimantan: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx mobile phone for Bontang LNG (Badak LNG), East Kalimantan

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesBontang LNG (Badak LNG), East Kalimantan: LNG liquefaction trains, LNG and LPG storage tanks, Gas pipelinesClassified by the site operator
Product · Bontang LNG

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Bontang LNG. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Bontang LNG (Badak LNG), East Kalimantan

Bontang LNG (Badak LNG), East Kalimantan at a glance: who is there, what is classified

A short profile of the site and the kinds of classified area that matter for portable equipment.

Operators and companies on site

  • Pertamina
  • PT Badak NGL

Classified areas to expect

  • LNG liquefaction trains
  • LNG and LPG storage tanks
  • Gas pipelines
  • Loading jetties
Local conditions · Bontang LNG (Badak LNG), East Kalimantan

Site conditions at Bontang LNG (Badak LNG), East Kalimantan: what wears and what limits equipment

History

The company was established in 1974 and the first train was completed on 5 July 1977.

Reduced operation

Declining feed gas has cut output since 2001. Reporting in 2025 put only two trains in operation, with reactivation of Train F targeted for October 2028 as new gas arrives.

Field notes · Bontang LNG (Badak LNG), East Kalimantan

More about Bontang LNG (Badak LNG), East Kalimantan that matters for portable equipment

Bontang LNG (Badak LNG), East Kalimantan: climate and equipment wear

Bontang has a tropical rainforest climate with warm, stable temperatures and abundant rain, a drier period from about May to September and a wetter one from November to May.

Bontang LNG (Badak LNG), East Kalimantan: industry on the ground

Coal mining company PT Indominco, owned by Banpu and active since 1977, extracts up to 11 million tonnes a year, so Bontang combines gas liquefaction, ammonia and coal dust hazards in one small city.

Bontang LNG (Badak LNG), East Kalimantan: geography and layout

Bontang sits on the Makassar Strait coast of East Kalimantan and has only 160 sq km of land, of which about 32 percent of its administrative area is dry land, so industrial sites sit close to the sea and town.

Bontang LNG (Badak LNG), East Kalimantan: people and language

Bontang Industrial Technology College (STTIB) is the city's best known higher education institution, supplying local technicians for the gas, fertiliser and coal industries.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In Bontang LNG (Badak LNG), East Kalimantan. A reviewer at Badak LNG would expect certificate evidence that traces to the equipment marking and its schedule of conditions. That evidence for the IS-04Z1 is in progress. A dual ATEX and IECEx route suits an LNG plant whose engineering and maintenance contractors work to international gas-industry practice.

The route · specification

Specifying an ATEX and IECEx mobile phone for Bontang LNG

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Bontang LNG

Frequently asked questions

Can we buy an ATEX and IECEx mobile phone in Bontang LNG today?

Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.

What does an ATEX and IECEx mobile phone in Bontang LNG cost?

There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

Which areas at Bontang LNG (Badak LNG), East Kalimantan would use it?

Likely candidates are lng liquefaction trains, lng and lpg storage tanks, gas pipelines, loading jetties. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

What kinds of hazardous areas are found around Bontang?

The main ones are LNG and natural-gas processing areas, ammonia and urea plants, and coal handling with combustible dust. Each operator classifies its own plant, so ask Badak LNG, Pupuk Kaltim or the mine for its zone drawings before bringing handheld devices on site.

Does the humid climate matter for phones used at Bontang plants?

Yes. A tropical rainforest climate with frequent heavy rain, warm stable temperatures and sea air tends to stress seals, connectors and chargers. Typically users specify good ingress protection and keep spare batteries and cleaning routines, subject to the plant's rules.

Will a handset at Bontang need to cope with marine conditions?

Jetties and coastal areas expose devices to heat, humidity and salt air. Check the rated temperature range, seals and charging contacts. Charge only in safe areas. Water and dust protection does not replace explosion protection. Confirm site practice with the operator.

Enquiry · Bontang LNG (Badak LNG), East Kalimantan

Ask about the IS-04Z1 for Bontang LNG (Badak LNG), East Kalimantan, Indonesia

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · Bontang LNG (Badak LNG), East Kalimantan

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Bontang LNG?

Name the site and the operator and we will send what is available before launch.