Indonesia: background
Pertamina was created in August 1968 by merging Pertamin, founded in 1961, and Permina, founded in 1957 from nationalised Shell assets, and it is headquartered in Jakarta.
A Zone 1 and Zone 21 handset for Indonesian operators, mechanics, inspectors and contractor crews working across an archipelago where the nearest replacement device is often a flight away. This page explains what to look for in a rugged mobile phone for Indonesia, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Indonesia: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ingress protection | IP65 to IP68 sealing | IP68 design |
| Drop and shock | A stated drop height onto concrete | Specification on request |
| Explosion protection | A separate certificate and marking | In progress; not issued |
| Where it applies | Indonesia: Cilacap, Central Java, Balikpapan, East Kalimantan, Dumai, Riau | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Indonesia. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Indonesia market guide.
Pertamina was created in August 1968 by merging Pertamin, founded in 1961, and Permina, founded in 1957 from nationalised Shell assets, and it is headquartered in Jakarta.
Pertamina operates six oil refineries with a combined capacity of around 1 million barrels a day, as of 2013, and has not built a new refinery since Balongan opened in West Java in the mid-1990s.
Radio and telecom equipment certification by SDPPI is compulsory in Indonesia, with a three-year validity, local testing and a local representative required, and a marking requirement.
Technical requirements for 5G devices follow Perdirgen No. 5/2021, so 5G-capable phones are tested against that rule as part of SDPPI certification.
A rugged phone is built to survive water, dust, drops and rough handling, usually rated by an IP code and a drop specification. Ruggedness is an environmental property: it says nothing about whether a phone may be used where flammable gas or dust is present. That is decided by explosion-protection certification and marking.
The IS-04Z1 combines both: an IP68 sealed rugged build and a design for Zone 1 and Zone 21 (marking target Ex ib IIC T4). The explosion-protection certificates are in progress and none has been issued.
In Indonesia. Indonesian sites face heat, humidity, heavy rain and salt air, and remote ones are far from replacement stock. IP68 sealing helps with water and dust ingress. It is an ingress rating, not explosion protection, which must come from certification. Battery behaviour in tropical heat should be tested on a trial unit.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
It is designed to IP68 sealing, with glove-friendly controls. Ruggedness is not explosion protection: that depends on the certificates, which are in progress.
The market guide for Indonesia covers Cilacap, Central Java, Balikpapan, East Kalimantan, Dumai, Riau, Balongan, West Java, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Tropical sites typically combine heat, high humidity, heavy rain and, near the coast, salt air, so check ingress protection, corrosion resistance and operating temperature range. Confirm site-specific requirements with the operator, including any area classification and approved-device lists.
With thousands of islands, many sites are reached by sea or air, and delays are common. Plan extra lead time and spares for devices, chargers and batteries, and ask the operator or contractor about shipping, customs and site approval rules for each island location.
Supply after certification would be through authorised distributors, and none has been appointed yet. For remote sites, ask about spares, replacement time and training before purchase, and agree the logistics route with the operator. Trial units can be tested to check connectivity and battery use first.
Related guides for Indonesia and for Indonesia.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.