Indonesia: infrastructure
Pertamina operates six oil refineries with a combined capacity of around 1 million barrels a day, as of 2013, and has not built a new refinery since Balongan opened in West Java in the mid-1990s.
A Zone 1 and Zone 21 handset for Indonesian operators, mechanics, inspectors and contractor crews working across an archipelago where the nearest replacement device is often a flight away. Pertamina was created in August 1968 by merging Pertamin, founded in 1961, and Permina, founded in 1957 from nationalised Shell assets, and it is headquartered in Jakarta. An ATEX and IECEx mobile phone distributor in Indonesia would carry the IS-04Z1 to these buyers once certification completes.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. Indonesia has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Marking | II 2 G Ex ib IIC T4 on the rating plate | Design target; not yet marked |
| EU-type examination certificate | Notified body number and certificate ID | In progress with TÜV; not issued |
| IECEx certificate of conformity | Number listed on the IECEx online register | In progress; not issued |
| Where it applies | Indonesia: Dumai, Riau, Balongan, West Java, Bontang, East Kalimantan | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Indonesia. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Operators and classified areas drawn from the SAMS Indonesia market guide.
Pertamina operates six oil refineries with a combined capacity of around 1 million barrels a day, as of 2013, and has not built a new refinery since Balongan opened in West Java in the mid-1990s.
Radio and telecom equipment certification by SDPPI is compulsory in Indonesia, with a three-year validity, local testing and a local representative required, and a marking requirement.
Technical requirements for 5G devices follow Perdirgen No. 5/2021, so 5G-capable phones are tested against that rule as part of SDPPI certification.
A market-access database lists CE and FCC among other schemes recognised in Indonesia, and notes that expired certificates cannot be renewed and must be tested again as a new model.
ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.
For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.
In Indonesia. An Indonesian reviewer would expect IECEx evidence plus the local route, including SNI, Komdigi type approval and TKDN, which the sheet lists as in progress. ATEX evidence helps international contractors working on LNG and offshore-support sites. A dual route lets one pack serve the operator and visiting teams. No certificate has been issued.
SAMS is appointing authorised distributors ahead of the Q4 2026 launch. No territory has been granted for Indonesia yet and applications are reviewed company by company. Because a certified Ex device cannot be opened by an ordinary phone workshop without invalidating its certificate, SAMS looks for partners who can provide competent technical support and after-sales service locally.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.
The market guide for Indonesia covers Cilacap, Central Java, Balikpapan, East Kalimantan, Dumai, Riau, Balongan, West Java, among others. Site-level pages are linked below.
Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for Indonesia.
Tropical sites typically combine heat, high humidity, heavy rain and, near the coast, salt air, so check ingress protection, corrosion resistance and operating temperature range. Confirm site-specific requirements with the operator, including any area classification and approved-device lists.
With thousands of islands, many sites are reached by sea or air, and delays are common. Plan extra lead time and spares for devices, chargers and batteries, and ask the operator or contractor about shipping, customs and site approval rules for each island location.
Supply after certification would be through authorised distributors, and none has been appointed yet. For remote sites, ask about spares, replacement time and training before purchase, and agree the logistics route with the operator. Trial units can be tested to check connectivity and battery use first.
More on Indonesia, and on other places in Indonesia.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.