Hydrogen
A hydrogen shipment centre began operating at the Daesan plant in November 2025.
In spring, strong winds carry fine Asian dust from the Chinese mainland, prompting many residents to wear masks, so dust protection and cleaning matter for equipment used outdoors. HD Hyundai Oilbank, which is headquartered in Seosan, and the merged H&L Advanced petrochemical business operate there, so process areas are Zone 1 and Zone 2. If you are specifying a rugged mobile phone for Daesan, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Daesan: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ingress protection | IP65 to IP68 sealing | IP68 design |
| Drop and shock | A stated drop height onto concrete | Specification on request |
| Explosion protection | A separate certificate and marking | In progress; not issued |
| Where it applies | Daesan: Naphtha cracker and petrochemical units, Refinery process units, Tank farms | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Daesan. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
A hydrogen shipment centre began operating at the Daesan plant in November 2025.
HD Hyundai Chemical absorbed Lotte Chemical's Daesan unit to form H&L Advanced, launched at the Daesan plant on 4 September 2026.
Seosan is the west coast transport hub where the Seohaean and Daejeon-Dangjin Expressways and National Highways 29, 32, 38 and 45 meet, which helps trucking and equipment delivery.
The summer monsoon lasts about three weeks in June or July with strong winds and heavy rain, and mild typhoons can affect the area in summer, so outdoor work is often rescheduled.
Upgrades completed by 2021 lifted Daesan capacity to about 1.5 million tonnes a year of ethylene and 1.1 million of propylene, and let the plant also crack propane.
HD Hyundai Chemical is owned 60% by HD Hyundai Oilbank and 40% by Lotte Chemical, and in late 2025 the partners agreed to consolidate their Daesan naphtha crackers, subject to ministry approval.
A rugged phone is built to survive water, dust, drops and rough handling, usually rated by an IP code and a drop specification. Ruggedness is an environmental property: it says nothing about whether a phone may be used where flammable gas or dust is present. That is decided by explosion-protection certification and marking.
The IS-04Z1 combines both: an IP68 sealed rugged build and a design for Zone 1 and Zone 21 (marking target Ex ib IIC T4). The explosion-protection certificates are in progress and none has been issued.
In Daesan. Daesan sits on the Yellow Sea coast, so wind, sea air and cold winter weather are part of the job for outdoor crews. IP68 sealing is designed in for the IS-04Z1 and helps in rain and dust. It is not explosion protection, and battery performance in cold weather should be tested.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
It is designed to IP68 sealing, with glove-friendly controls. Ruggedness is not explosion protection: that depends on the certificates, which are in progress.
Likely candidates are naphtha cracker and petrochemical units, refinery process units, tank farms, hydrogen handling. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Daesan is part of Seosan on the Yellow Sea coast, about 125 km south of Seoul, and the area is served by the Seohaean Expressway and several national highways. Most visitors travel by road from Seoul or Daejeon, so plan equipment transport accordingly.
Spring Asian dust, a short but heavy summer monsoon, occasional typhoons and cold winters all occur. Typically devices need good dust and water ingress protection and a reliable battery in the cold, and sites may pause outdoor work in severe weather.
Yes. Hydrogen is a Group IIC gas, so equipment for those areas needs a suitable gas-group marking. The IS-04Z1 target marking includes IIC but no certificate has been issued. Ask the operator which Daesan areas it classes as hydrogen hazards.
Other guides for Daesan, other places in South Korea, and the pages behind them.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.