ExxonMobil
ExxonMobil states it owns and operates a 592,000-barrel-per-day refinery integrated with its chemical plant, with three cogeneration facilities producing around 440 MW.
Singapore's crude refining is run by ExxonMobil, Singapore Refining Company and Aster, with facilities on Jurong Island and Pulau Bukom. Process units, tank farms and jetties create Zone 1 and Zone 2 areas. If you are specifying an intrinsically safe smartphone for Singapore refineries, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Singapore refineries: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Level of protection | ia, ib or ic matched to the zone | ib, for Zone 1 |
| Entity parameters | Uo, Io and Po within the device limits | Published with the certificate |
| Accessories | Chargers and cases certified with the device | Defined at certification |
| Where it applies | Singapore refineries: Refinery process units, Crude and product storage, Jetties | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Singapore Refinery. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
ExxonMobil states it owns and operates a 592,000-barrel-per-day refinery integrated with its chemical plant, with three cogeneration facilities producing around 440 MW.
Singapore Petroleum Company holds a 50% interest in SRC, whose refinery can process 290,000 barrels of crude per day; Chevron holds the other 50%.
Visitors surrender contraband such as matches and lighters, declare cameras, computers and laptops, wear a security pass at all times and stay with their sponsor inside the refinery.
Staff and visitors reach Jurong Island by bus from Lakeside MRT or Jurong East, with some employers running private shuttles from the checkpoint to their premises.
Singapore Refining Company operates a Jurong Island refinery capable of processing 290,000 barrels of crude oil a day, supplying fuel products and chemical feedstocks to domestic and export markets.
The refinery's main entrance is reached via Merlimau Road along Jurong Island Highway, after a stop at the Jurong Island Checkpoint where visitors collect a visitor pass.
Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.
The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.
In Singapore refineries. Refinery operators walk long routes through process units, utilities and storage, and turnaround crews inspect equipment in tight windows. A handheld intrinsically safe phone is designed to carry photographs, readings and checklists on those rounds. It depends on certification in progress and on each refinery's permit and inspection systems.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.
Likely candidates are refinery process units, crude and product storage, jetties, utility and cogeneration areas. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
One refinery states a crude capacity of 290,000 barrels a day, and other operators share the island. The scale means many contractors, so expect formal induction, permits and equipment checks for any portable electronics.
Refineries usually route equipment queries through procurement and the process safety or HSE function, with reliability and maintenance teams as end users. Ask your sponsor for the correct contacts and the current approved-equipment procedure.
No. The refineries use their own approval and contractor systems, so acceptance at one does not carry over to another. The IS-04Z1 has no certificate yet. Send the datasheet to each operator's procurement and HSE teams and confirm with the site operator.
Other guides for Singapore Refinery, other places in Singapore, and the pages behind them.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.