Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Thailand · intrinsically safe

Intrinsically Safe Mobile Phone in Thailand

A Zone 1 and Zone 21 handset for the people inside the Thai petrochemical cluster: shift operators on the Map Ta Phut crackers, reliability engineers at Sriracha, jetty and tank farm crews along the Rayong coast, and the safety and IT departments that rule on what passes a gate. If you are specifying an intrinsically safe mobile phone for Thailand, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Thailand, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicintrinsically safe
DeviceMobile Phone
RouteSpecification
WhereThailand

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Thailand: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Current position: certification in progress, nothing issued, launch targeted for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.

At a glance · intrinsically safe

Checklist: intrinsically safe mobile phone for Thailand

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
Level of protectionia, ib or ic matched to the zoneib, for Zone 1
Entity parametersUo, Io and Po within the device limitsPublished with the certificate
AccessoriesChargers and cases certified with the deviceDefined at certification
Where it appliesThailand: Map Ta Phut Industrial Estate, Rayong industrial estates, Sriracha, ChonburiClassified by the site operator
Product · Thailand

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Thailand. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Thailand

Where this applies in Thailand

The classified areas, operators and sites below are the ones covered in the SAMS Thailand market guide.

Operators, EPCs and contractors

PTT Global Chemical
Olefins, aromatics and derivatives across the Map Ta Phut complex
SCG Chemicals
Crackers, polyolefin and downstream plants at Map Ta Phut
IRPC
Integrated refinery and petrochemical complex at Rayong
Star Petroleum Refining
Refinery and jetty operations at Map Ta Phut
Thai Oil
The refinery and downstream units at Sriracha, Chonburi
ExxonMobil
Refinery and chemical operations at Sriracha

Industrial areas and sites

Map Ta Phut Industrial Estate
The IEAT petrochemical estate: crackers, derivatives and the deep sea port
Rayong industrial estates
Asia, RIL, Hemaraj and the neighbouring estates around Map Ta Phut
Sriracha, Chonburi
Two refineries, lube plants and the associated tank farms
Laem Chabang
The container and bulk port, chemical berths and the industrial estate behind it
Chachoengsao
EEC industrial estates and the plants along the Bang Pakong corridor
Gulf of Thailand
Offshore production platforms, wellhead platforms and the supply bases
Field notes · Thailand

More about Thailand that matters for portable equipment

Thailand: industry on the ground

Natural gas makes up about 27% of Thailand's total energy supply and fuels roughly 64% of electricity generation, so gas processing, pipelines and power plants dominate classified-area work.

Thailand: industry on the ground

The transport sector uses nearly half of oil products and oil is 41% of total energy supply, so fuel depots, filling terminals and distribution sites occur across the whole country.

Thailand: geography and layout

As of March 2024 Thailand had 34 active petroleum projects across 47 oil fields in the Gulf of Thailand, so offshore platform and supply-base work is a large part of upstream activity.

Thailand: projects and investment

The Eastern Economic Corridor, set up in 2017, spans three eastern provinces covering 13,266 square kilometres, and follows the earlier Eastern Seaboard programme that financed ports, roads, waterworks and industrial parks.

The term · intrinsically safe

What “intrinsically safe” means for a smartphone

Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.

The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.

In Thailand. Intrinsic safety suits the long shifts and gate discipline of the Rayong estates and the Sriracha refineries, where a worker may carry a single device through many areas. A handheld that limits ignition energy lets crews photograph, log and communicate on a round without leaving the zone, including on open pipe racks.

The route · specification

Specifying an intrinsically safe mobile phone for Thailand

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Thailand

Frequently asked questions

Can we buy an intrinsically safe mobile phone in Thailand today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an intrinsically safe mobile phone in Thailand cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

What does ‘intrinsically safe’ mean for the IS-04Z1?

The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.

Which sites in Thailand does this cover?

The market guide for Thailand covers Map Ta Phut Industrial Estate, Rayong industrial estates, Sriracha, Chonburi, Laem Chabang, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Do Thai plants usually accept IECEx or ATEX certified devices?

Many operators, particularly those with international ownership, work to IEC 60079 and accept IECEx or ATEX paperwork, but this is decided by each site's own safety procedure. Ask for the approved equipment list and supply the certificate and marking details with your request.

What gas-related facilities in Thailand typically need Zone 1 devices?

Gas processing plants, pipeline stations, LNG receiving terminals, power stations using gas and offshore platforms are typical examples, given that gas fuels about 64% of electricity. Zone classification is site specific, so request the hazardous-area layout drawings.

What approvals are involved for use in Thailand?

The sheet describes certification under way with IECEx, the TISI and the NBTC route. None has been issued yet. A buyer should ask for the schedule and check the final certificates against site and regulator requirements before use.

Enquiry · Thailand

Ask about the IS-04Z1 for Thailand

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Thailand

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Thailand?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.