Portugal: infrastructure
The Sines LNG import terminal has three storage tanks with a total capacity of 390,000 cubic metres and regasification capacity of 5.6 million tonnes a year, making Sines Portugal's key gas import site.
The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, aimed at the refining and polymer complex at Sines, the chemical plants at Estarreja and the pulp, cement and mining sites in between. This page explains what to look for in an industrial cell phone for Portugal, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Portugal: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ingress protection | IP rating for dust and water | IP68 design |
| Fleet management | EMM and MDM support | Android 16 with EMM and MDM |
| Explosion protection | A separate certificate and marking | In progress; not issued |
| Where it applies | Portugal: Sines, ZILS Alentejo, Estarreja | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Portugal. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS Portugal market guide covers.
The Sines LNG import terminal has three storage tanks with a total capacity of 390,000 cubic metres and regasification capacity of 5.6 million tonnes a year, making Sines Portugal's key gas import site.
In 2000 about 85% of Portugal's energy was imported, so most fuel and gas reaches the country through port terminals rather than domestic fields.
Sines on the Atlantic coast hosts an important oil refinery and several petrochemical industries.
Portugal aims to cover 80% of electricity consumption with renewables by 2030 and has developed a hydrogen strategy to reduce gas imports, which may add hydrogen-classified areas.
“Industrial” describes a phone built for plant conditions: sealed, drop-resistant and manageable at fleet scale through Android Enterprise. It does not by itself mean the phone may enter a classified area. Only a device with a valid explosion-protection certificate and marking may do that.
The IS-04Z1 is designed to be both an industrial Android phone (IP68, 4,000 mAh battery, 50 MP camera, Android 16 with EMM and MDM support) and an intrinsically safe one. Its explosion-protection certificates are in progress and have not been issued.
In Portugal. Sites are large and crews are small, with long distances to anyone who can service equipment. Android 16 with EMM and MDM lets a central team manage devices across plants, with Portuguese on the screen and in the file. Charge in a safe area, since one charge should cover one shift.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
Yes by design: IP68 sealing, a 4,000 mAh battery, a 50 MP camera and Android 16 with EMM and MDM support. The explosion-protection certificates are separate and still in progress.
The market guide for Portugal covers Sines, ZILS Alentejo, Estarreja, Matosinhos and Leça, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Portugal is an EU member, so ATEX Directive 2014/34/EU applies to equipment and Directive 1999/92/EC to workplace zoning. Zone 1 and Zone 2 devices should carry CE and Ex markings with instructions in Portuguese where required. Operators usually add their own permit and registration procedures.
Sines hosts Portugal's LNG import terminal, with three storage tanks totalling 390,000 cubic metres and a regasification capacity of 5.6 million tonnes a year. Terminal and port operators set their own induction and device rules, so confirm them before sending equipment.
Yes, Zone 21 dust protection belongs to the same certification programme as the gas marking. In pulp, cement and mineral processing the powder area is the plant, not a corner of it, so check the final certificate and the site's own dust classification with the operator.
Other guides for Portugal, other places in Portugal, and the pages behind them.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.