Strategic storage
India's strategic petroleum reserve includes a 1.5 million tonne underground facility at Mangaluru, with a further one at nearby Padur.
Mangaluru has a tropical monsoon climate, with about 95 percent of annual rainfall from May to September and a very dry period from December to March. These create hazardous areas in processing and storage. This page explains what to look for in an IECEx mobile phone for Mangaluru (Mangalore), Karnataka, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Mangaluru (Mangalore), Karnataka: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Certificate of conformity | Number checkable on the IECEx online register | In progress; not issued |
| Standards edition | The IEC 60079 edition the certificate cites | Stated on the certificate when issued |
| Schedule of conditions | Limits of use, batteries and accessories | Published with the certificate |
| Where it applies | Mangaluru (Mangalore), Karnataka: Refinery process units, Petrochemical aromatics and polypropylene units, Underground crude storage caverns | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Mangalore India. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
India's strategic petroleum reserve includes a 1.5 million tonne underground facility at Mangaluru, with a further one at nearby Padur.
MRPL was established in 1988, is a subsidiary of ONGC and has a design capacity of 15 million tonnes a year, including a polypropylene unit.
Humidity averages about 75 percent and peaks at around 93 percent in July, with a lowest average of about 56 percent in January.
The city is one of the locations of India's strategic petroleum reserves, which adds crude storage facilities to the area.
The new port opened in 1968, handles about 75 percent of India's coffee and cashew exports and is India's seventh-largest container port.
ONGC held about 71.6 percent of MRPL and HPCL about 17 percent as of 2020, so the refinery sits inside the public-sector oil group.
IECEx is the international scheme for certifying equipment used in explosive atmospheres. A certificate of conformity is issued by an accredited certification body against a specific edition of the IEC 60079 standards and carries a schedule of conditions of safe use. It is not a legal requirement in most countries on its own, but many national schemes accept it as the technical basis.
The IECEx certificate for the IS-04Z1 is in progress and has not been issued. The marking target is Ex ib IIC T4, the intrinsic safety concept for Zone 1 gas with the hardest gas group (IIC) and a 135 °C temperature class.
In Mangaluru (Mangalore), Karnataka. MRPL, OMPL and the strategic reserve each use specialist contractors, some of them international. IECEx evidence, meaning a certificate of conformity with its schedule of conditions, is a reference they commonly recognise. SAMS is pursuing IECEx for the IS-04Z1, and nothing has been issued.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
No. The IECEx certificate is in progress and has not been issued. SAMS will publish the number when it exists.
Likely candidates are refinery process units, petrochemical aromatics and polypropylene units, underground crude storage caverns, marine terminal. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
The refinery includes crude distillation, hydrocrackers, reformers and a polypropylene unit, with tank farms and port connections, all with classified areas defined by the operator. Request the area classification before entering.
The period from December to March is very dry, while 95 percent of the annual rain falls between May and September. Many operators schedule outdoor work accordingly.
No. They are run by different organisations, so each classifies its own areas and sets its own equipment rules. Confirm with MRPL and with the SEZ petrochemical operator separately. Approval at one does not imply approval at the other.
Other guides for Mangalore India, other places in India, and the pages behind them.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.