Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Canada · IECEx

IECEx Mobile Phone in Canada

The IS-04Z1 is an Ex phone for people working inside classified areas at Canadian oil sands plants, gas plants, refineries and offshore platforms. If you are specifying an IECEx mobile phone for Canada, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Canada, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicIECEx
DeviceMobile Phone
RouteSpecification
WhereCanada

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Canada: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.

At a glance · IECEx

Checklist: IECEx mobile phone for Canada

Checks a reviewer should make, with the IS-04Z1 position
CheckWhat to look forIS-04Z1 today
Certificate of conformityNumber checkable on the IECEx online registerIn progress; not issued
Standards editionThe IEC 60079 edition the certificate citesStated on the certificate when issued
Schedule of conditionsLimits of use, batteries and accessoriesPublished with the certificate
Where it appliesCanada: Athabasca oil sands, Cold Lake and the Lakeland, Alberta Industrial HeartlandClassified by the site operator
Product · Canada

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Canada. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Canada

Where this applies in Canada

The classified areas, operators and sites below are the ones covered in the SAMS Canada market guide.

Operators, EPCs and contractors

Suncor Energy
Base Plant, Fort Hills, Sarnia and Edmonton refining
Cenovus Energy
Foster Creek, Christina Lake, Lloydminster, offshore Atlantic
Imperial Oil
Kearl and Cold Lake, Strathcona and Sarnia refineries
Canadian Natural Resources
Horizon and Albian mining, Jackfish and Primrose thermal
Syncrude
Mildred Lake mining and upgrading, operated by Suncor
Shell Canada
Scotford upgrader, refinery and chemicals in the Heartland

Industrial areas and sites

Athabasca oil sands
Fort McMurray mines, upgraders and in situ plants
Cold Lake and the Lakeland
Thermal in situ pads and steam generation
Alberta Industrial Heartland
Fort Saskatchewan, Scotford and Redwater refining and chemicals
Montney and Duvernay
Gas plants around Grande Prairie and Fort St John
Sarnia Chemical Valley
Three refineries and dozens of chemical plants
Kitimat and the north coast
LNG Canada trains and jetty, Cedar LNG building
Field notes · Canada

More about Canada that matters for portable equipment

Canada: rules and approvals

Radio and wireless devices sold in Canada need ISED certification against the Radio Standards Specifications, such as RSS-247 for Wi-Fi and Bluetooth and RSS-Gen for general requirements and labelling.

Canada: climate and equipment wear

Fort McMurray averages minus 17.2 degrees Celsius in January, with a recorded low of minus 53.3 degrees, so batteries, touchscreens and enclosures need to work in deep cold.

Canada: rules and approvals

Canada also accepts field certification for custom-made or low-volume equipment, evaluated at the installation site, which is similar to unit verification under the IECEx and ATEX systems.

Canada: rules and approvals

Hazardous locations in Canada fall under Section 18 of the Canadian Electrical Code Part I, which uses the Zone system, while the older Class and Division rules are kept in Annex J for existing installations.

The term · IECEx

What “IECEx” means for a smartphone

IECEx is the international scheme for certifying equipment used in explosive atmospheres. A certificate of conformity is issued by an accredited certification body against a specific edition of the IEC 60079 standards and carries a schedule of conditions of safe use. It is not a legal requirement in most countries on its own, but many national schemes accept it as the technical basis.

The IECEx certificate for the IS-04Z1 is in progress and has not been issued. The marking target is Ex ib IIC T4, the intrinsic safety concept for Zone 1 gas with the hardest gas group (IIC) and a 135 °C temperature class.

In Canada. IECEx is the scheme visiting international operators and EPCs may bring to Canada, from Kitimat LNG to the Grand Banks, but Rule 18-050 requires equipment certified by a body accredited by the Standards Council of Canada. The certificate of conformity and schedule of conditions would be read alongside that. Nothing has been issued yet.

The route · specification

Specifying an IECEx mobile phone for Canada

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Canada

Frequently asked questions

Can we buy an IECEx mobile phone in Canada today?

Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.

What does an IECEx mobile phone in Canada cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

Does the IS-04Z1 hold an IECEx certificate?

No. The IECEx certificate is in progress and has not been issued. SAMS will publish the number when it exists.

Which sites in Canada does this cover?

The market guide for Canada covers Athabasca oil sands, Cold Lake and the Lakeland, Alberta Industrial Heartland, Montney and Duvernay, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Does a phone for Canadian oil sands sites need Canadian certification?

Hazardous-location electrical equipment in Canada is generally expected to carry certification from a Standards Council of Canada accredited body, and IECEx or ATEX certificates are not accepted as a substitute, although they can speed the evaluation. Confirm the required marking with the site operator and a Canadian certification body.

How cold-tolerant should devices be for northern Alberta?

Fort McMurray averages about minus 17 degrees Celsius in January and has seen extremes below minus 50, so check the datasheet's operating and charging temperature range, battery behaviour in cold, and glove-friendly controls. Confirm any site cold-weather procedures with the operator before deployment.

Will the battery work on cold winter shifts?

Every battery gives up capacity in the cold, and the 4,000 mAh cell is sized for a normal shift, not extreme cold. Unless a certificate says otherwise, hazardous area equipment is assessed for minus 20 to plus 40 degrees Celsius, and the marked range will be published when the certificate issues. Check it first.

Enquiry · Canada

Ask about the IS-04Z1 for Canada

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Canada

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Canada?

Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.