Australia: rules and approvals
ANZEx has been owned by JAS-ANZ since August 2016, and Queensland's Electrical Safety Regulation 2026 took effect on 1 September 2026, so state rules continue to evolve.
A Zone 1 / Zone 21 smartphone for crews on Australian LNG trains, offshore facilities, processing plants and remote mine sites. Australia works on the IECEx scheme and the AS/NZS 60079 series, and the national ANZEx scheme is harmonised with IECEx, so IECEx-certified equipment can be used almost without separate national testing. An IECEx cell phone distributor in Australia would carry the IS-04Z1 to these buyers once certification completes.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. Australia has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Certificate of conformity | Number checkable on the IECEx online register | In progress; not issued |
| Standards edition | The IEC 60079 edition the certificate cites | Stated on the certificate when issued |
| Schedule of conditions | Limits of use, batteries and accessories | Published with the certificate |
| Where it applies | Australia: Darwin, Gladstone and Curtis Island, Bowen Basin, Queensland | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Australia. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS Australia market guide covers.
ANZEx has been owned by JAS-ANZ since August 2016, and Queensland's Electrical Safety Regulation 2026 took effect on 1 September 2026, so state rules continue to evolve.
Operators typically check for a current IECEx or ANZEx certificate, a suitable gas group and temperature class, a Hazardous Area Verification Dossier under AS/NZS 60079.14 and installer competency.
An IECEx certificate for an assembly of several items is not automatically accepted unless it is validated against the current AS/NZS 60079.14 or the assembly is independently inspected.
The Australian Communications and Media Authority regulates the supply of radiocommunications equipment and made rule changes in 2023 to simplify and streamline that regulation.
IECEx is the international scheme for certifying equipment used in explosive atmospheres. A certificate of conformity is issued by an accredited certification body against a specific edition of the IEC 60079 standards and carries a schedule of conditions of safe use. It is not a legal requirement in most countries on its own, but many national schemes accept it as the technical basis.
The IECEx certificate for the IS-04Z1 is in progress and has not been issued. The marking target is Ex ib IIC T4, the intrinsic safety concept for Zone 1 gas with the hardest gas group (IIC) and a 135 °C temperature class.
In Australia. Australia takes part directly in the IECEx system, and AS/NZS 60079 is harmonised with IEC 60079, so the certificate of conformity is the practical basis for equipment at Woodside, Chevron, INPEX, Shell and Santos sites. The reviewer reads the schedule of conditions for ambient range and special conditions. The ANZEx certificate would follow from the same test reports.
A distributor for Australia would carry the IS-04Z1 after certification completes; the Q4 2026 launch is the planning date and no appointment has been made. SAMS reviews applicants one by one and prefers companies with their own Ex-competent technical and service staff, since certified devices must not be repaired outside approved channels.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
No. The IECEx certificate is in progress and has not been issued. SAMS will publish the number when it exists.
The market guide for Australia covers Karratha and the Burrup Peninsula, Onslow, Western Australia, Darwin, Gladstone and Curtis Island, among others. Site-level pages are linked below.
Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for Australia.
The Pilbara is hot, dry and dusty, with long distances between sites and towns. Check the operating temperature range, dust ingress rating and battery life in heat, and confirm with the operator any site rules on permits, inductions and mobile devices in classified areas.
It is the installation documentation expected under AS/NZS 60079.14, showing that the equipment, its certificate and its installation suit the classified area. Operators and inspectors look for it before energising equipment, so ask the site electrical team what must be supplied with portable and fixed equipment.
The target marking is T4 with the ambient range to be fixed on the certificate, which is not yet issued. The 4,000 mAh battery is sized for a roster day with radio, camera and GNSS running. Check the certified range against your site's worst summer ambient and trial a unit before fleet orders.
More on Australia, and on other places in Australia.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.