Portugal: who works there
Galp Energia, formed in 1999 from Petrogal, Gás de Portugal and Transgás, is Portugal's largest oil and gas group, with business units covering upstream, refining and midstream, commercial, and renewables.
The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, aimed at the refining and polymer complex at Sines, the chemical plants at Estarreja and the pulp, cement and mining sites in between. If you are specifying a hazardous area mobile phone for Portugal, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Portugal: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Zone | 0, 1 or 2 for gas; 20, 21 or 22 for dust | Designed for Zone 1 and Zone 21 |
| Gas group | IIA, IIB or IIC | IIC (target) |
| Area drawing | The operator's own classification drawing | Decided by the site operator |
| Where it applies | Portugal: Sines, ZILS Alentejo, Estarreja | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Portugal. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Portugal market guide.
Galp Energia, formed in 1999 from Petrogal, Gás de Portugal and Transgás, is Portugal's largest oil and gas group, with business units covering upstream, refining and midstream, commercial, and renewables.
The Sines hard coal power plant operated from 1985-1989 until January 2021 and coal-fired generation ended in 2021, so former coal sites are being redeveloped.
Oil made up 44% of Portugal's total energy supply in 2023, so fuel storage, port terminals and distribution depots form a large part of the classified-area infrastructure.
In 2021 Portugal imported 2.8 billion cubic metres of LNG from Nigeria, almost 50% of its gas imports that year, so ship-to-shore LNG operations are central to gas supply.
A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.
No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.
In Portugal. Portuguese classified areas include the Sines refinery, polymer complex, LNG terminal and port, Estarreja chemicals, former refinery storage at Matosinhos, cement and pulp at Setúbal, Figueira da Foz and Aveiro, and the Neves-Corvo mine. The operator classifies each area, so SAMS does not issue drawings.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.
The market guide for Portugal covers Sines, ZILS Alentejo, Estarreja, Matosinhos and Leça, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Atlantic coastal sites are salt-laden and summers can be hot, so check the maximum ambient temperature on the certificate, the water and dust ingress rating and the condition of charging contacts. Sealed connectors and regular cleaning are typically recommended for coastal terminals.
Portugal has a hydrogen strategy aimed at reducing gas imports by 2030, so hydrogen projects may create new classified areas. Hydrogen belongs to a more demanding gas group than propane, so check the gas group marking of a device against the project's area classification.
Sites such as Sines or the Alentejo interior can be far from anyone who services equipment, so a reachable service route matters. SAMS has appointed no distributor yet. Before purchase, ask what repair, replacement and battery support would be available for your plant, and agree it in writing.
More on Portugal, and on other places in Portugal.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.