Singapore: projects and investment
SLNG plans a second LNG terminal offshore, slated to operate by the end of the decade, in addition to the existing Jurong Island terminal, so new gas-handling sites are expected over the coming years.
The IS-04Z1 is an intrinsically safe Zone 1 and Zone 21 handset for people who work inside classified areas on Jurong Island, at Pulau Bukom and around the Tuas terminals: process operators, inspection and maintenance engineers, turnaround crews and the WSH and IT teams who equip them. This page explains what to look for in an explosion proof smartphone for Singapore, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Singapore: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Protection concept | Flameproof (Ex d) or intrinsic safety (Ex i) | Intrinsic safety, level ib |
| Zone suitability | Zone 1 gas and Zone 21 dust | Design target for Zone 1 and 21 |
| Certificate | Number, issuing body and schedule of conditions | In progress; not issued |
| Where it applies | Singapore: Jurong Island, Pulau Bukom, Seraya and Merbau | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Singapore. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS Singapore market guide covers.
SLNG plans a second LNG terminal offshore, slated to operate by the end of the decade, in addition to the existing Jurong Island terminal, so new gas-handling sites are expected over the coming years.
IMDA registers telecommunications equipment under a supplier's declaration approach. Cellular mobile devices, including 5G and LTE, fall under Simplified Equipment Registration, while base stations and similar higher-risk products need a recognised certification body.
An IMDA equipment registration is valid for five years, renewal is filed through the GoBusiness portal at least two months before expiry, and suppliers must keep test reports and technical files for five years.
Tuas Port opened on 1 September 2022 and is planned to reach 65 million TEU of annual handling capacity in the 2040s, which concentrates future cargo flows in the far west of the island.
“Explosion proof” is the phrase most buyers use for equipment that may be taken into a classified hazardous area. Strictly, it covers several protection concepts: a flameproof enclosure (Ex d) contains an internal explosion, while intrinsic safety (Ex i) limits electrical energy so that an ignition cannot start. Phones are normally intrinsically safe, because a flameproof handset would be too heavy to carry all shift.
The IS-04Z1 uses intrinsic safety, with a marking target of Ex ib IIC T4, and is designed for Zone 1 and Zone 21. It is pre-launch, certification is in progress and no certificate has been issued.
In Singapore. Explosion-proof is used loosely on the island, but the plants hold varied atmospheres. A flameproof Ex d enclosure suits fixed equipment, while intrinsic safety, the protection concept of the IS-04Z1, limits the energy of a handheld. On Jurong Island the practical question is which concept a handset uses for hydrogen or acetylene areas.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
It is intrinsically safe (marking target Ex ib IIC T4), which is the usual way to make a phone for hazardous areas. It is not a flameproof (Ex d) design, and certification is still in progress.
The market guide for Singapore covers Jurong Island, Pulau Bukom, Seraya and Merbau, Pulau Sebarok and Pulau Busing, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Singapore adopts IEC 60079 as SS EN 60079, and both IECEx and ATEX certificates are built on that technical base. Many operators accept either, but an individual refinery or yard may name one scheme in its specification, so confirm with the operator's HSE or instrumentation team.
Cellular mobile devices are generally registered with IMDA under the Simplified Equipment Registration route, which relies on a supplier's declaration of conformity. The registration is valid for five years, and the registering supplier is typically a local entity. Confirm the exact route for a specific model with IMDA or a local compliance adviser.
The design pairs a 4,000 mAh battery with IP68 sealing so the unit lasts through a shift where a spare may be a boat away. Charging stays in a safe area. Test battery life on a typical round and confirm access rules with the island operator.
Other guides for Singapore, other places in Singapore, and the pages behind them.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Name the site and the operator and we will send what is available before launch.