Jordan: projects and investment
Modern renewables made up 10% of final energy consumption in 2020, up from 3% in 2015, and developers sell power to the National Electric Power Company, so solar and wind construction is increasing.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in Jordan every shift: potash and phosphate plant operators, refinery crews at Zarqa, port operators at Aqaba, and the HSE and telecoms teams who equip them. If you are specifying an explosion proof cell phone for Jordan, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Jordan: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Protection concept | Flameproof (Ex d) or intrinsic safety (Ex i) | Intrinsic safety, level ib |
| Zone suitability | Zone 1 gas and Zone 21 dust | Design target for Zone 1 and 21 |
| Certificate | Number, issuing body and schedule of conditions | In progress; not issued |
| Where it applies | Jordan: Dead Sea works, Eshidiya, Al-Hasa and Al-Abiad | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Jordan. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS Jordan market guide covers.
Modern renewables made up 10% of final energy consumption in 2020, up from 3% in 2015, and developers sell power to the National Electric Power Company, so solar and wind construction is increasing.
In 2021 Jordan's total energy supply was 51% oil, 38% gas, 3% coal and 8% renewables, so fuel storage, gas networks and power stations form its main flammable-materials infrastructure.
The Arab Potash Company holds a concession to 2058 to extract Dead Sea minerals, has its main plants at Ghor Al Safi, and is the eighth-largest potash producer worldwide.
The Jordan Petroleum Refinery Company's activities include refining, filling gas cylinders, a lubricant factory and fuel marketing through JoPetrol, so one operator spans several hazardous-area process types.
“Explosion proof” is the phrase most buyers use for equipment that may be taken into a classified hazardous area. Strictly, it covers several protection concepts: a flameproof enclosure (Ex d) contains an internal explosion, while intrinsic safety (Ex i) limits electrical energy so that an ignition cannot start. Phones are normally intrinsically safe, because a flameproof handset would be too heavy to carry all shift.
The IS-04Z1 uses intrinsic safety, with a marking target of Ex ib IIC T4, and is designed for Zone 1 and Zone 21. It is pre-launch, certification is in progress and no certificate has been issued.
In Jordan. Explosion-proof is a common phrase, but Jordan's heaviest exposure is dust at potash and phosphate sites, with gas at Zarqa refinery and Aqaba. Flameproof Ex d suits some fixed gear; an intrinsically safe handset suits a worker moving between plants. The IS-04Z1 is designed around intrinsic safety for Zone 1 and Zone 21.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
It is intrinsically safe (marking target Ex ib IIC T4), which is the usual way to make a phone for hazardous areas. It is not a flameproof (Ex d) design, and certification is still in progress.
The market guide for Jordan covers Dead Sea works, Eshidiya, Al-Hasa and Al-Abiad, Zarqa, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Operators commonly work to IEC 60079 and accept ATEX or IECEx certificates, but acceptance is set by each site's own procedure. Ask the operator's HSE team for its approved equipment list and provide certificates, marking details and manufacturer instructions with your request.
The Zarqa refinery, run by the Jordan Petroleum Refinery Company, is the best-known, with refining, LPG filling and lubricants activity. Expansion and modernisation projects are planned or under way, so contractors work there. Confirm current access rules and device approvals with the company.
The market guide says Jordan's heaviest classified-area exposure is dust, at potash and phosphate sites, with gas at the refinery and Aqaba. Which applies depends on the area. Ask the operator for the zone classification, covering both dust and gas, before choosing a device.
Related guides for Jordan and for Jordan.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.