Jordan: projects and investment
Modern renewables made up 10% of final energy consumption in 2020, up from 3% in 2015, and developers sell power to the National Electric Power Company, so solar and wind construction is increasing.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in Jordan every shift: potash and phosphate plant operators, refinery crews at Zarqa, port operators at Aqaba, and the HSE and telecoms teams who equip them. If you are specifying an Ex-proof mobile phone for Jordan, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Jordan: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | Jordan: Dead Sea works, Eshidiya, Al-Hasa and Al-Abiad | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Jordan. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Jordan market guide.
Modern renewables made up 10% of final energy consumption in 2020, up from 3% in 2015, and developers sell power to the National Electric Power Company, so solar and wind construction is increasing.
In 2021 Jordan's total energy supply was 51% oil, 38% gas, 3% coal and 8% renewables, so fuel storage, gas networks and power stations form its main flammable-materials infrastructure.
The Arab Potash Company holds a concession to 2058 to extract Dead Sea minerals, has its main plants at Ghor Al Safi, and is the eighth-largest potash producer worldwide.
The Jordan Petroleum Refinery Company's activities include refining, filling gas cylinders, a lubricant factory and fuel marketing through JoPetrol, so one operator spans several hazardous-area process types.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In Jordan. A Jordanian marking check would compare dust capability, gas group, category and temperature class with the zone plan. Dust at potash and phosphate plants and gas at the refinery and fuel terminals may need different checks. The IS-04Z1 marking target is II 2 G Ex ib IIC T4; it is not a granted marking.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
The market guide for Jordan covers Dead Sea works, Eshidiya, Al-Hasa and Al-Abiad, Zarqa, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Operators commonly work to IEC 60079 and accept ATEX or IECEx certificates, but acceptance is set by each site's own procedure. Ask the operator's HSE team for its approved equipment list and provide certificates, marking details and manufacturer instructions with your request.
The Zarqa refinery, run by the Jordan Petroleum Refinery Company, is the best-known, with refining, LPG filling and lubricants activity. Expansion and modernisation projects are planned or under way, so contractors work there. Confirm current access rules and device approvals with the company.
The market guide says Jordan's heaviest classified-area exposure is dust, at potash and phosphate sites, with gas at the refinery and Aqaba. Which applies depends on the area. Ask the operator for the zone classification, covering both dust and gas, before choosing a device.
Other guides for Jordan, other places in Jordan, and the pages behind them.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.