Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Poland · Ex-proof

Ex-Proof Smartphone Supplier in Poland

The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, built for the refinery, fertiliser and gas terminal work where Polish teams actually meet an explosive atmosphere. Buyers searching for an Ex-proof smartphone supplier for Poland can take the datasheet and the certification schedule for the IS-04Z1 now; supply follows certification.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Poland, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicEx-proof
DeviceSmartphone
RouteSupply
WherePoland

Short answer. An Ex-proof smartphone for Poland cannot be bought yet: the SAMS IS-04Z1 is pre-launch (certification in progress, no certificate issued), and the datasheet, certification schedule and safe-area evaluation units are available now.

Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.

At a glance · Ex-proof

Checklist: Ex-proof smartphone for Poland

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
Ex markingGroup, category, protection concept, gas group, temperature classII 2 G Ex ib IIC T4 (target)
Gas groupIIA, IIB or IIC matched to the area drawingIIC (target)
Temperature classT-class below the ignition temperature of the gasT4, 135 °C (target)
Where it appliesPoland: Police, Tarnów, PłockClassified by the site operator
Product · Poland

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Poland. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Poland

Where this applies in Poland

The classified areas, operators and sites below are the ones covered in the SAMS Poland market guide.

Operators, EPCs and contractors

Orlen
Płock and Gdańsk refineries and the Płock petrochemical complex.
Orlen Południe
Biorefining and base oil plants at Trzebinia and Jedlicze.
Anwil
PVC, caustic soda and nitrogen fertilisers at Włocławek.
Grupa Azoty
Nitrogen and chemical plants at Tarnów, Puławy and Police.
Grupa Azoty Polyolefins
The Polimery Police propylene and polypropylene complex.
Gaz-System
Transmission grid, Baltic Pipe and the Świnoujście LNG terminal.

Industrial areas and sites

Płock
The largest refining and petrochemical complex in the country.
Gdańsk
Coastal refinery, oil terminal and pipeline tank farms.
Włocławek
Chlorine, PVC and fertiliser plants on the Vistula.
Puławy
Nitrogen fertiliser and melamine production in Lublin province.
Police
Fertiliser complex and the new polypropylene units on the Oder.
Tarnów
The original Azoty nitrogen and plastics site in Małopolska.
Field notes · Poland

More about Poland that matters for portable equipment

Poland: infrastructure

Bełchatów Power Station in the Łódź region supplies almost 20% of Poland's energy and is the largest brown coal power plant in the EU, a major example of a large dust-hazard site.

Poland: projects and investment

Solar energy expanded by 51.39% in 2023 and 26.61% in 2024 while hard coal fell 16.96% in 2024, and nuclear power is being introduced, so the types of site are changing.

Poland: industry on the ground

The Płock refinery and petrochemical complex is the largest oil refinery in Poland, and Orlen's headquarters are in the same city, with servicing and construction firms clustered around the plant.

Poland: industry on the ground

Coal use splits into 75.6% for electricity and heat, 14.5% for industry and 9.9% for buildings, so industrial coal consumers beyond power plants also have dust and gas hazards.

The term · Ex-proof

What “Ex-proof” means for a smartphone

“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.

The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.

In Poland. A marking check in Poland compares II 2 G Ex ib IIC T4 with the plant's classification. The gas marking target covers refineries and gas terminals, while Zone 21 dust protection belongs to the same programme. On a fertiliser site, the prilling tower, bagging hall and ammonia area can sit close together, so each area's zone must be confirmed.

The route · supply

Sourcing the IS-04Z1 for Poland

There is no stock to order for Poland yet. The IS-04Z1 is pre-launch, certification is in progress, and supply will run through authorised distributors after the certificates are issued. Procurement teams can prepare now with the datasheet, the certification schedule and a safe-area evaluation.

  1. 01

    Request the datasheet

    The technical specification, marking target and conditions of use, sent by email.

  2. 02

    Ask for the certification schedule

    Which certificates are in progress, in what order, and what is still to be confirmed.

  3. 03

    Evaluate in a safe area

    Evaluation units can be used for connectivity, MDM enrolment and workflow testing outside classified areas.

  4. 04

    Register for launch

    Tell us the site, zone, gas group and quantity so the right authorised distributor can contact you.

Questions · Poland

Frequently asked questions

Can we buy an Ex-proof smartphone in Poland today?

Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.

What does an Ex-proof smartphone in Poland cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

What Ex marking will the IS-04Z1 carry?

The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.

Which sites in Poland does this cover?

The market guide for Poland covers Płock, Gdańsk, Włocławek, Puławy, among others. Site-level pages are linked below.

How will SAMS supply Poland?

Through authorised distributors once certificates exist. Until then SAMS can send the datasheet and certification schedule and arrange safe-area evaluation units.

What language should Polish sites receive documentation in?

Polish is the working language and ATEX instructions are typically expected in the language of the destination country. A Polish-language instruction sheet with certificate pack usually speeds up site acceptance. Ask the operator whether English documents are also accepted for contractors.

Does Poland follow ATEX for handheld devices in hazardous areas?

Poland is an EU member, so ATEX Directive 2014/34/EU applies to equipment and Directive 1999/92/EC to workplace zoning. Zone 1 and Zone 2 devices should carry CE and Ex markings with instructions in Polish. Operators and mines usually add their own approval rules.

Does one device cover both gas and dust on a fertiliser site?

The gas marking target is II 2 G Ex ib IIC T4, and Zone 21 dust protection belongs to the same programme, so one device is designed to cover both. Certification is in progress, so confirm the final marking and the plant's zone drawing with the operator.

Enquiry · Poland

Ask about the IS-04Z1 for Poland

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · Poland

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Poland?

Name the site and the operator and we will send what is available before launch.