Hot humid climate
Heat, humidity and coastal salt are normal.
The Port of Rio de Janeiro is the third-busiest in Brazil, with a 6.7 km pier, 31 berths and drafts of 10 to 15 metres, and it handles petrochemicals among its cargoes, with road and rail access. Hazardous-area work in the surrounding state is at refineries, terminals and shipyards in neighbouring municipalities such as Duque de Caxias, Angra dos Reis, Itaborai and Niteroi. If you are specifying an Ex-proof smartphone for Rio de Janeiro, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Rio de Janeiro: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | Rio de Janeiro: Refinery process units (Duque de Caxias), Shipyards and FPSO yards, Tank terminals | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Rio de Janeiro. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
A short profile of the site and the kinds of classified area that matter for portable equipment.
Heat, humidity and coastal salt are normal.
Petrobras' headquarters is in downtown Rio, which concentrates decision-making and many service companies.
The 2007 and 2008 Santos Basin pre-salt discoveries (Tupi, Jupiter and Sugar Loaf) lie about 300 km off the coast of Rio de Janeiro, tying the city to deepwater supply and service work.
Galeao International Airport lies on Governador Island in Guanabara Bay, while Santos Dumont Airport is the city's second airport, so equipment and visitors can arrive at two separate airfields.
Rio was founded in 1565, became seat of the Portuguese court in 1808 and stands on Guanabara Bay, with the Rio-Niteroi Bridge a landmark route to the Niteroi side of the bay.
Rio has the second-largest municipal GDP in Brazil and is home to the headquarters of major oil, mining and telecommunications companies, including Petrobras and Vale, concentrating decision-makers in one city.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In Rio de Janeiro. A marking check begins by asking which site the handset will enter: Reduc, a Guanabara Bay shipyard, a tank terminal or an offshore base. Each classification differs. Compare zone, gas group and temperature class with the label. The IS-04Z1 target marking II 2 G Ex ib IIC T4 is not yet certified.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
Likely candidates are refinery process units (duque de caxias), shipyards and fpso yards, tank terminals, offshore support bases. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Rio's coastal setting is warm and humid, so spare devices are best kept in dry cases with desiccant and checked for condensation before use. Confirm storage guidance in the warehouse or base procedures.
Mostly in the port, fuel terminals and refining sites around Guanabara Bay rather than in the central city. Check the exact location with the project, because zones are set by each facility's classification study.
Reduc at Duque de Caxias, about 17 km from downtown, Guanabara Bay shipyards such as Brasa at Niteroi, Angra dos Reis and Itaborai. Each has its own classification and rules. Confirm approvals and documentation requirements with the site operator.
More on Rio de Janeiro, and on other places in Brazil.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.