Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Peru · Ex-proof

Ex-Proof Smartphone in Peru

The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in Peru every shift: copper mine and concentrator operators, Camisea gas-field crews, refinery engineers, and the HSE and telecoms teams who equip them. If you are specifying an Ex-proof smartphone for Peru, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Peru, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicEx-proof
DeviceSmartphone
RouteSpecification
WherePeru

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Peru: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.

At a glance · Ex-proof

Checklist: Ex-proof smartphone for Peru

Checks a reviewer should make, with the IS-04Z1 position
CheckWhat to look forIS-04Z1 today
Ex markingGroup, category, protection concept, gas group, temperature classII 2 G Ex ib IIC T4 (target)
Gas groupIIA, IIB or IIC matched to the area drawingIIC (target)
Temperature classT-class below the ignition temperature of the gasT4, 135 °C (target)
Where it appliesPeru: Cuajone / Toquepala, Antamina, Cerro VerdeClassified by the site operator
Product · Peru

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Peru. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Peru

Hazardous-area industry in Peru

The main operators, industrial areas and sites that the SAMS Peru market guide covers.

Operators, EPCs and contractors

Southern Copper Corporation
Grupo México subsidiary operating Cuajone and Toquepala
Compañía Minera Antamina
BHP, Glencore, Teck and Mitsubishi joint-venture copper-zinc mine
Cerro Verde
Freeport-McMoRan copper mine near Arequipa
Las Bambas
MMG copper mine in Apurímac
Petroperú
State oil company — Talara and other refineries
Camisea consortium operators
Natural gas production in the Cusco Amazon foothills

Industrial areas and sites

Cuajone / Toquepala
Southern Copper’s high-altitude open-pit mines and smelters
Antamina
Copper-zinc mine and concentrator in Ancash
Cerro Verde
Concentrator and processing complex near Arequipa
Las Bambas
Copper mine and concentrate pipeline in Apurímac
Camisea
Gas fields and processing plant in the Cusco Amazon lowlands
Talara
Petroperú refinery on the northern coast
Field notes · Peru

More about Peru that matters for portable equipment

Peru: infrastructure

The 540 kilometre Camisea pipeline crosses the steep Andes to the Pisco terminal in the Paracas National Reservation, passing the Malvinas plant where LPG liquids are separated from the gas.

Peru: rules and approvals

A testing partner reports that Peruvian homologation needs no local laboratory tests or local representative, certificates have unlimited validity, and there are no extra labelling requirements.

Peru: rules and approvals

Type approval for radio equipment in Peru is run by the Ministerio de Transportes y Comunicaciones, MTC, and is based on American FCC standards.

Peru: industry on the ground

The Camisea gas project in the Cusco Region started operating in August 2004, in a remote forested part of the Amazon Basin on the Urubamba River with a largely Indigenous population.

The term · Ex-proof

What “Ex-proof” means for a smartphone

“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.

The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.

In Peru. A marking check in Peru compares II 2 G Ex ib IIC T4 with the area drawing. Camisea and Talara are the gas and vapour Zone 1 case, while copper and zinc concentrators at altitude bring persistent fine dust, which is why the Zone 21 target matters. Temperature class and altitude conditions should be confirmed with the operator.

The route · specification

Specifying an Ex-proof smartphone for Peru

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Peru

Frequently asked questions

Can we buy an Ex-proof smartphone in Peru today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an Ex-proof smartphone in Peru cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

What Ex marking will the IS-04Z1 carry?

The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.

Which sites in Peru does this cover?

The market guide for Peru covers Cuajone / Toquepala, Antamina, Cerro Verde, Las Bambas, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

How should devices handle high-altitude mining in the Andes?

At altitude the air is thin and cold, with strong sun and sharp temperature swings, so check the operating temperature range, battery behaviour in cold and any altitude rating on the datasheet. Confirm site limits with the mine operator, who may also restrict where devices can be taken underground.

Do remote jungle sites such as Camisea need special support planning?

Yes. Camisea is a remote, forested site in the Amazon Basin, so deliveries and repairs are slow. Plan spare devices, chargers and batteries, and ask the operator or contractor about transport, camp rules, permits and device approval before dispatching equipment.

Is Spanish supported on the handset?

Android 16 carries both Spanish and English interface languages on the same handset, which suits operations with local and international technical staff. Interface language is a software matter and separate from certification. Check with your IT team which language packs and apps your fleet policy requires.

Enquiry · Peru

Ask about the IS-04Z1 for Peru

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Peru

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Peru?

Name the site and the operator and we will send what is available before launch.