Hydrogen
A hydrogen shipment centre began operating at the Daesan plant in November 2025.
Seosan is the west coast transport hub where the Seohaean and Daejeon-Dangjin Expressways and National Highways 29, 32, 38 and 45 meet, which helps trucking and equipment delivery. HD Hyundai Oilbank, which is headquartered in Seosan, and the merged H&L Advanced petrochemical business operate there, so process areas are Zone 1 and Zone 2. This page explains what to look for in an Ex-proof smartphone for Daesan, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Daesan: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | Daesan: Naphtha cracker and petrochemical units, Refinery process units, Tank farms | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Daesan. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The companies on site and the hazardous-area types a handset is likely to meet there.
A hydrogen shipment centre began operating at the Daesan plant in November 2025.
HD Hyundai Chemical absorbed Lotte Chemical's Daesan unit to form H&L Advanced, launched at the Daesan plant on 4 September 2026.
Seosan had a population of roughly 175,000 in the 2017 census, which sets the scale of the local labour pool beside the coastal industrial area.
Daesan lies within Seosan city on the Yellow Sea coast of South Chungcheong Province, about 125 km south of Seoul and 34 km north-west of Naepo New Town.
The Daesan refining and petrochemical platform is a 50/50 joint venture between Hanwha and TotalEnergies, commissioned in 1991 and covering about 3.3 million square metres, making fuels and polymers on one integrated site.
In spring, strong winds carry fine Asian dust from the Chinese mainland, prompting many residents to wear masks, so dust protection and cleaning matter for equipment used outdoors.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In Daesan. Process areas are Zone 1 and Zone 2, and hydrogen handling is present. Hydrogen is Group IIC, so a marking check should look at the gas group as well as zone and temperature class. The IS-04Z1 target marking, II 2 G Ex ib IIC T4, includes IIC but has not been issued.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
Likely candidates are naphtha cracker and petrochemical units, refinery process units, tank farms, hydrogen handling. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Daesan is part of Seosan on the Yellow Sea coast, about 125 km south of Seoul, and the area is served by the Seohaean Expressway and several national highways. Most visitors travel by road from Seoul or Daejeon, so plan equipment transport accordingly.
Spring Asian dust, a short but heavy summer monsoon, occasional typhoons and cold winters all occur. Typically devices need good dust and water ingress protection and a reliable battery in the cold, and sites may pause outdoor work in severe weather.
Yes. Hydrogen is a Group IIC gas, so equipment for those areas needs a suitable gas-group marking. The IS-04Z1 target marking includes IIC but no certificate has been issued. Ask the operator which Daesan areas it classes as hydrogen hazards.
More on Daesan, and on other places in South Korea.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.