Japan: rules and approvals
Radio equipment falls under the Telec technical conformity scheme of the communications ministry, and a certified-products database can be searched to check a model.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in Japan every shift: refinery and petrochemical-complex operators, LNG terminal crews, inspection engineers, and the HSE and telecoms teams who equip them. The Keiyo Industrial Zone runs along the north-eastern coast of Tokyo Bay through eight cities in Chiba Prefecture, from Urayasu to Futtsu, including Chiba, Kisarazu and Ichihara. Distribution partners for Japan are being identified ahead of the Q4 2026 launch of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. Japan has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | Japan: Mizushima, Chiba / Sodegaura, Yokkaichi | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Japan. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS Japan market guide covers.
Radio equipment falls under the Telec technical conformity scheme of the communications ministry, and a certified-products database can be searched to check a model.
Small rivers, including the Edo River, supply water to the Keiyo industrial region, and the Port of Chiba serves the zone.
Explosion-protected electrical equipment must pass type examination, called kentei, under Article 44-2 of the Industrial Safety and Health Act, and equipment without the pass mark may not be used.
The type examination involves a sample for structural inspection, with no factory audit in law, and the applicant can be a Japanese or foreign manufacturer or an importer.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In Japan. A Japanese marking check would compare gas group, dust capability, category and temperature class with the complex's zone plan. Refining, petrochemical and LNG areas can differ, so the group needed follows the operator's classification. The IS-04Z1 marking target is II 2 G Ex ib IIC T4, and it is not a granted marking.
A distributor for Japan would carry the IS-04Z1 after certification completes; the Q4 2026 launch is the planning date and no appointment has been made. SAMS reviews applicants one by one and prefers companies with their own Ex-competent technical and service staff, since certified devices must not be repaired outside approved channels.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
The market guide for Japan covers Kashima, Mizushima, Chiba / Sodegaura, Yokkaichi, among others. Site-level pages are linked below.
Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for Japan.
Explosion-protected electrical equipment must pass type examination under Article 44-2 of the Industrial Safety and Health Act, and equipment without the pass mark may not be used. Registered examination bodies, including some outside Japan, carry it out. Check the current process with one of them.
Typically in coastal industrial zones such as the Keiyo zone along Tokyo Bay, which has refineries and chemical plants, and similar bayside complexes elsewhere. The operator issues the area classification, so request the zone drawing, gas group and temperature class before selecting equipment.
The market guide lists TIIS and IECEx as in progress and neither has been granted. Whether a given site needs TIIS depends on the operator and the regulations it follows. Ask the site operator and check the current certification status before ordering.
Other guides for Japan, other places in Japan, and the pages behind them.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Name the site and the operator and we will send what is available before launch.