Turkey: industry on the ground
In 2019 primary energy was about 30% oil, 30% coal and 25% gas, and over 85% of energy came from fossil fuels, so refining, gas and coal sites provide most classified-area work.
The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, built for refinery and petrochemical work at Aliağa and on the Marmara, gas terminal and pipeline operations, and the fertiliser and chemical plants inside the organised industrial zones. This page explains what to look for in an Ex-proof mobile phone for Turkey, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Turkey: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | Turkey: Aliağa, Körfez and Kocaeli, Marmara Ereğlisi | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Turkey. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Turkey market guide.
In 2019 primary energy was about 30% oil, 30% coal and 25% gas, and over 85% of energy came from fossil fuels, so refining, gas and coal sites provide most classified-area work.
Turkey mines its own lignite but imports three-quarters of its energy, including half its coal and almost all the oil and gas it needs, so ports, pipelines and storage terminals are central.
Tüpraş operates four refineries handling about 30 million tonnes of crude a year, with Izmit and Izmir (Aliağa) at 11 million tonnes each, Kırıkkale at 5 million and Batman at 1.1 million.
A nuclear power plant is under construction and about half of installed power capacity is renewable, so construction and commissioning sites are active alongside existing plants.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In Turkey. A Turkish marking check reads II 2 G Ex ib IIC T4, with the T4 target and ambient range published in the datasheet instead of promised in advance, because a device that derates in the heat gets left in the control room. Fertiliser and fine inland dust bring Zone 21 into the same review.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
The market guide for Turkey covers Aliağa, Körfez and Kocaeli, Marmara Ereğlisi, Ceyhan, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Refining and petrochemical complexes, gas and crude oil pipelines, LNG and fuel terminals, coal and lignite mines and power stations are the main examples, and Black Sea gas is a growing area. Request zone drawings from each operator, as classifications are site specific.
Turkey has aligned its equipment rules with the EU ATEX approach, but its own conformity marking and local requirements may apply to products placed on its market. Confirm the current requirement with the site operator or your importer before ordering, and ask about documentation language.
The T4 target and certified ambient range will be published with the datasheet and certificate, which are in progress. IP68 sealing and a rugged build cover salt, dust and wash-down. Check the range against peak summer temperatures at your tank farm before specifying.
Related guides for Turkey and for Turkey.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Name the site and the operator and we will send what is available before launch.