Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Germany · Ex-proof

Ex-Proof Mobile Phone in Germany

The IS-04Z1 is an eigensicheres Smartphone designed to ATEX 2014/34/EU for Zone 1 and Zone 21, built for the chemical parks, refineries and pharmaceutical plants where most German Ex-Schutz work happens. This page explains what to look for in an Ex-proof mobile phone for Germany, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Germany, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicEx-proof
DeviceMobile Phone
RouteSpecification
WhereGermany

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Germany: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Current position: certification in progress, nothing issued, launch targeted for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · Ex-proof

Checklist: Ex-proof mobile phone for Germany

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
Ex markingGroup, category, protection concept, gas group, temperature classII 2 G Ex ib IIC T4 (target)
Gas groupIIA, IIB or IIC matched to the area drawingIIC (target)
Temperature classT-class below the ignition temperature of the gasT4, 135 °C (target)
Where it appliesGermany: Ludwigshafen, Leverkusen, MarlClassified by the site operator
Product · Germany

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Germany. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Germany

Where an Ex phone is used in Germany

Operators and classified areas drawn from the SAMS Germany market guide.

Operators, EPCs and contractors

BASF
Ludwigshafen, the largest contiguous chemical site in the world.
Currenta
Runs the Chempark sites at Leverkusen, Dormagen and Krefeld-Uerdingen.
Evonik
Chemiepark Marl and specialty chemical production.
Infraserv Höchst
Site operator for Industriepark Höchst in Frankfurt.
Wacker Chemie
Silicon and silicone production at Burghausen.
LANXESS
Specialty chemicals at Krefeld-Uerdingen and Leverkusen.

Industrial areas and sites

Ludwigshafen
BASF Verbund site, around 10 km² and roughly 200 plants.
Leverkusen
Chempark site on the Rhine shared by dozens of companies.
Marl
Chemiepark with crackers and downstream derivative plants.
Frankfurt Höchst
Industriepark shared by chemical and pharmaceutical producers.
Burghausen
Bavarian chemical triangle, refining and silicone production.
Karlsruhe
MiRO, the largest refinery in Germany, on the upper Rhine.
Field notes · Germany

More about Germany that matters for portable equipment

Germany: industry on the ground

BASF says its Ludwigshafen Verbund site covers about ten square kilometres, makes it the world's largest integrated chemical complex, and has 125 production plants, with roughly a third of BASF employees worldwide based there.

Germany: rules and approvals

Manufacturers may self-certify ATEX Category 3 equipment with a technical dossier including a user manual in the local language, while Category 1 and 2 generally need a notified body.

Germany: logistics and access

Norway supplied the largest share of both Germany's gas and crude oil imports in 2025, and German LNG terminals accounted for 10.3% of natural gas imports, so LNG import sites are a new classified-area category.

Germany: projects and investment

Germany plans to phase out coal-fired electricity generation by 2038 at the latest and aims for renewables to supply at least 80% of gross electricity consumption by 2030.

The term · Ex-proof

What “Ex-proof” means for a smartphone

“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.

The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.

In Germany. A German marking check would compare the device's category, gas group, dust capability and temperature class with the zone documentation for each plant. Chemical-park gas service can involve hydrogen and other groups, so IIC capability helps. The IS-04Z1 target is II 2 G Ex ib IIC T4, and it remains a target until certification is complete.

The route · specification

Specifying an Ex-proof mobile phone for Germany

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Germany

Frequently asked questions

Can we buy an Ex-proof mobile phone in Germany today?

Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.

What does an Ex-proof mobile phone in Germany cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

What Ex marking will the IS-04Z1 carry?

The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.

Which sites in Germany does this cover?

The market guide for Germany covers Ludwigshafen, Leverkusen, Marl, Frankfurt Höchst, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Where are German LNG and fuel import sites?

German LNG terminals supplied about 10.3% of natural gas imports in 2025, and crude, products and coal arrive through ports and pipelines. Individual terminal locations and rules change, so confirm the current list and each operator's contractor requirements before planning work.

What hazardous areas exist in Germany's lignite regions?

Lignite is mined in North Rhine-Westphalia, Saxony and Brandenburg and burned at nearby power plants, so coal dust, conveyor and bunker areas are typical dust zones. Choose devices with a dust group marking suited to the area classification, and check with the operator.

Does a German site accept an international certificate?

Acceptance is the decision of the operator and its approved inspection body. ATEX is the usual reference for equipment in the EU, and IECEx papers may support a review. Ask the site's explosion protection officer which evidence they require before ordering.

Enquiry · Germany

Ask about the IS-04Z1 for Germany

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · Germany

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Germany?

Name the site and the operator and we will send what is available before launch.