Separate regional administration
The Kurdistan Region has its own ministries and company registration processes, which can differ from federal Iraq.
Erbil is the capital of the Kurdistan Region of Iraq and a hub for the region's oil and gas companies. The Kalak refinery of KAR Group, in Kalak district about 40 km west of the city, processes crude from nearby fields and creates refinery and fuel-storage hazardous areas. Distribution partners for Erbil and the Kurdistan Region are being identified ahead of the Q4 2026 launch of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. Erbil and the Kurdistan Region has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | Erbil and the Kurdistan Region: Refinery process units, Fuel storage and loading, Gas and field production facilities in the region | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Erbil. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The companies on site and the hazardous-area types a handset is likely to meet there.
The Kurdistan Region has its own ministries and company registration processes, which can differ from federal Iraq.
Erbil International Airport is one of Iraq's busiest, which helps equipment and personnel reach the region.
Erbil International Airport has a 4,800 metre runway and a terminal designed for up to 4.5 million passengers a year, around 7 km from the city centre.
Iraq's Communications and Media Commission issues type approval certificates valid for one year for telecommunications equipment sold in the country.
Erbil is the capital and most populated city of the Kurdistan Region of Iraq, and is described as the region's economic, industrial and medical hub.
The Citadel of Erbil, at the heart of the old city, was inscribed as a World Heritage Site in July 2014, and the area is one of the oldest continuously inhabited places in the world.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In Erbil and the Kurdistan Region. At a refinery, loading rack or field facility in the region, a marking check means reading the label for zone, gas group and temperature class, then matching each to the operator's classification file. Fuel vapours are common, and the IS-04Z1 target marking II 2 G Ex ib IIC T4 would be compared with that file, not assumed.
SAMS is appointing authorised distributors ahead of the Q4 2026 launch. No territory has been granted for Erbil and the Kurdistan Region yet and applications are reviewed company by company. Because a certified Ex device cannot be opened by an ordinary phone workshop without invalidating its certificate, SAMS looks for partners who can provide competent technical support and after-sales service locally.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
Likely candidates are refinery process units, fuel storage and loading, gas and field production facilities in the region. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for Erbil and the Kurdistan Region.
The Kurdistan Region has its own regional government and administration, so permits, entry arrangements and company registration may differ from Baghdad. Confirm requirements with your host before travel.
Erbil International Airport has a very long 4,800 metre runway and can handle passenger and cargo flights, which is convenient for urgent equipment shipments. Customs clearance is handled by your freight agent.
No. Refinery process units and fuel loading areas can be classified hazardous, and an ordinary phone is not designed for them. Only equipment suitable for the zone and approved by the operator should enter. The IS-04Z1 is intended for such areas but is not yet certified.
More on Erbil, and on other places in Iraq.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.