Complex
Alongside the refinery, Indian Oil runs a naphtha cracker and PX-PTA units producing ethylene, propylene, paraxylene and purified terephthalic acid.
Panipat in Haryana hosts Indian Oil's refinery and petrochemical complex at Baholi, which began operating in 1998 and now processes 15 million tonnes a year. Process units, a naphtha cracker and tank farms create Zone 1 areas. This page explains what to look for in an ATEX and IECEx mobile phone for Panipat, Haryana, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Panipat, Haryana: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Marking | II 2 G Ex ib IIC T4 on the rating plate | Design target; not yet marked |
| EU-type examination certificate | Notified body number and certificate ID | In progress with TÜV; not issued |
| IECEx certificate of conformity | Number listed on the IECEx online register | In progress; not issued |
| Where it applies | Panipat, Haryana: Refinery process units, Naphtha cracker and petrochemical units, Product tank farms | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Panipat India. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
A short profile of the site and the kinds of classified area that matter for portable equipment.
Alongside the refinery, Indian Oil runs a naphtha cracker and PX-PTA units producing ethylene, propylene, paraxylene and purified terephthalic acid.
Indian Oil's board approved expansion from 15 to 25 million tonnes a year; recent reports put full commissioning around December 2026, so project contractors are active on site.
Paraxylene and purified terephthalic acid units were commissioned in June 2006, and a naphtha cracker complex next door makes ethylene and propylene for polymers.
The city is also known as the city of weavers and a textile centre, with wool and cotton milling, glass and electrical appliance manufacturing.
The refinery produces ultra-low sulphur diesel under BS VI norms and has four ambient air monitoring stations that predate its start-up.
Panipat is 95 kilometres north of Delhi and 169 kilometres south of Chandigarh on NH-44.
ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.
For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.
In Panipat, Haryana. Panipat's refinery and petrochemical complex runs a naphtha cracker and large expansion works, so reviewers include plant HSE and project contractors. A dual ATEX and IECEx route helps international contractors on the expansion. The IS-04Z1 has no certificate yet, and both routes are in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.
Likely candidates are refinery process units, naphtha cracker and petrochemical units, product tank farms, loading gantries. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
The refinery has process units, hydrogen and cracker areas, tank farms and loading facilities, and the naphtha cracker complex adds ethylene and propylene handling. The operator defines classified areas, so request the drawings before visiting.
Yes, the refinery has paraxylene and PTA units and a naphtha cracker complex alongside it. The units may have different operators and rules, so ask each site.
Cold can reduce battery capacity and fog adds moisture, so sealing and warm storage between uses help. An IP68 housing handles moisture ingress. Ask the operator about its rules for portable equipment outdoors in winter and where devices may be kept warm.
Related guides for Panipat India and for India.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.