Austria: industry on the ground
Machinery and equipment, vehicles, chemicals, metals, and iron and steel are leading sectors, so chemical plants, foundries and paint and coating lines add solvent and dust hazards beyond oil and gas.
The IS-04Z1 is an ex proof phone designed to ATEX 2014/34/EU for gas and dust atmospheres, built for refinery turnarounds, gas stations on the transit grid, steel works and fibre plants. This page explains what to look for in an ATEX and IECEx cell phone for Austria, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Austria: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Marking | II 2 G Ex ib IIC T4 on the rating plate | Design target; not yet marked |
| EU-type examination certificate | Notified body number and certificate ID | In progress with TÜV; not issued |
| IECEx certificate of conformity | Number listed on the IECEx online register | In progress; not issued |
| Where it applies | Austria: Schwechat, Baumgarten an der March, Linz | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Austria. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Austria market guide.
Machinery and equipment, vehicles, chemicals, metals, and iron and steel are leading sectors, so chemical plants, foundries and paint and coating lines add solvent and dust hazards beyond oil and gas.
OMV AG, an integrated oil, gas and petrochemical group, is Austria's largest energy business, with a turnover of about 36 billion euros in 2021, and its refining and chemicals sites are typical Zone 1 and Zone 2 workplaces.
Transport used 31.3% of energy in 2021, the largest share of any sector, and the last coal plant closed in 2020, so fuel logistics and gas networks are the main thermal energy infrastructure.
Imported oil supplied 35.4% of energy consumed in 2022 and gas 16.8%, so pipelines, storage and distribution terminals form a large share of Austria's flammable-materials infrastructure.
ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.
For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.
In Austria. On the product side Austria is short: ATEX 2014/34/EU, transposed by the Explosionsschutzverordnung 2015, is the whole requirement. A reviewer would ask for the notified body certificate, the EU declaration of conformity and CE marking, in German. An IECEx route alongside helps groups that also operate outside the EU. The certification programme is in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.
The market guide for Austria covers Schwechat, Baumgarten an der March, Linz, Donawitz and Leoben, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Yes, as an EU member Austria applies ATEX Directive 2014/34/EU to equipment, and workplaces are zoned under Directive 1999/92/EC. Devices for Zone 1 or Zone 2 areas normally need the Ex marking, CE marking and documentation. Check the operator's list of accepted categories.
OMV AG is the largest energy business, with integrated oil, gas and petrochemical activity, so it is a major source of classified areas. Other sites include chemical plants and utility sites. Supplier approval is run by each company, so contact its procurement and safety teams.
No: ATEX 2014/34/EU, transposed by the Explosionsschutzverordnung 2015, is the whole product-side requirement and there is no separate Austrian product approval. The employer's duties sit under the VEXAT, which is where evaluation time goes. SAMS holds no ATEX certificate yet. Confirm what your site's explosion protection document needs.
Related guides for Austria and for Austria.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Name the site and the operator and we will send what is available before launch.