South Africa: industry on the ground
South Africa is the world's largest producer of chrome, manganese, platinum and vanadium and the third-largest coal exporter, so mining is a major source of hazardous-area work.
A Zone 1 / Zone 21 smartphone for crews at the Secunda and Sasolburg complexes, the Natref and Cape Town refineries, Mossel Bay, the fuel terminals and the surface plants of South African mining. This page explains what to look for in a rugged smartphone for South Africa, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for South Africa: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ingress protection | IP65 to IP68 sealing | IP68 design |
| Drop and shock | A stated drop height onto concrete | Specification on request |
| Explosion protection | A separate certificate and marking | In progress; not issued |
| Where it applies | South Africa: Secunda, Mpumalanga, Sasolburg, Free State, Milnerton, Cape Town | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in South Africa. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Operators and classified areas drawn from the SAMS South Africa market guide.
South Africa is the world's largest producer of chrome, manganese, platinum and vanadium and the third-largest coal exporter, so mining is a major source of hazardous-area work.
The code references a family of SANS standards, including SANS 10086 on installation, inspection and maintenance of equipment in explosive atmospheres, SANS 1489 on connectors and SANS 1515 on gas measuring equipment for mines.
ICASA, based in Centurion, sets radio type approval, relying on EU test reports for spectrum, EMC and electrical safety, and a conformity label must be affixed to the equipment and the packaging.
South Africa has a National Code of Practice for Electrical Machinery in Hazardous Locations under the Occupational Health and Safety Act 1993, with a section on regulatory requirements for explosion-protected apparatus.
A rugged phone is built to survive water, dust, drops and rough handling, usually rated by an IP code and a drop specification. Ruggedness is an environmental property: it says nothing about whether a phone may be used where flammable gas or dust is present. That is decided by explosion-protection certification and marking.
The IS-04Z1 combines both: an IP68 sealed rugged build and a design for Zone 1 and Zone 21 (marking target Ex ib IIC T4). The explosion-protection certificates are in progress and none has been issued.
In South Africa. Highveld summers are hot, winter mornings are cold and storms are violent, with coal and mineral dust over everything. IP68 sealing keeps water and dust out, and the certificate will state the approved ambient range. IP68 is an ingress rating and gives no protection against explosion.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
It is designed to IP68 sealing, with glove-friendly controls. Ruggedness is not explosion protection: that depends on the certificates, which are in progress.
The market guide for South Africa covers Secunda, Mpumalanga, Sasolburg, Free State, Milnerton, Cape Town, Mossel Bay, Western Cape, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
ICASA sets radio type approval, and it is described as relying on EU test reports covering spectrum use, EMC and electrical safety, with a conformity label on the equipment and packaging. SABS and NRCS handle some electrical-safety certificates separately. Confirm the route for your device with ICASA or an agent.
Conditions vary from hot, dusty surface sites to deep underground workings with heat and humidity. Check ingress protection, operating temperature range and battery life, and confirm site rules on device approval and gas detection with the mine or plant operator.
IP68 sealing and a rugged build are aimed at hot summers, cold winter mornings and dusty conditions. The approved ambient range will be stated on the certificate, which is in progress. Check that range against the coldest morning shift at your site before ordering.
Other guides for South Africa, other places in South Africa, and the pages behind them.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.