Czech Republic: infrastructure
In 2022 electricity production was 78.8 TWh, of which 53.6% came from fossil fuels, mostly lignite, and 40.95% from nuclear, so coal-handling plants and power stations are typical dust and gas sites.
The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, built for Czech refineries, chemical plants, tank farms and coke ovens rather than for a catalogue. State operator MERO finished expanding the Transalpine pipeline at the end of 2024, delivering up to 8 million tonnes of oil a year, with the central oil depot at Nelahozeves as a key storage point. Distribution partners for Czech Republic are being identified ahead of the Q4 2026 launch of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. Czech Republic has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ingress protection | IP65 to IP68 sealing | IP68 design |
| Drop and shock | A stated drop height onto concrete | Specification on request |
| Explosion protection | A separate certificate and marking | In progress; not issued |
| Where it applies | Czech Republic: Neratovice, Valašské Meziříčí, Pardubice | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Czech Republic. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Czech Republic market guide.
In 2022 electricity production was 78.8 TWh, of which 53.6% came from fossil fuels, mostly lignite, and 40.95% from nuclear, so coal-handling plants and power stations are typical dust and gas sites.
ATEX equipment is split into Group I for mining and Group II for surface industries, which matters in a country with coal mining as well as refining and chemicals.
Gas use was 9.4 billion cubic metres in 2021 and 7.1 billion in 2023, so gas distribution and industrial gas burners remain widespread across Czech industry.
The country has two refineries, both owned by Česká rafinérská, including the Litvínov refinery, so Litvínov and Kralupy are the best-known flammable-liquid processing sites.
A rugged phone is built to survive water, dust, drops and rough handling, usually rated by an IP code and a drop specification. Ruggedness is an environmental property: it says nothing about whether a phone may be used where flammable gas or dust is present. That is decided by explosion-protection certification and marking.
The IS-04Z1 combines both: an IP68 sealed rugged build and a design for Zone 1 and Zone 21 (marking target Ex ib IIC T4). The explosion-protection certificates are in progress and none has been issued.
In Czech Republic. Czech plants face cold winter rounds on tank farms and the wash-down regime of chemical plants. IP68 sealing and a rugged build, including low temperature and humidity, are designed for that. The certified ambient range is stated on the datasheet once the certificate fixes it. IP68 is not explosion protection, which comes from the ATEX certificate.
Distribution of the IS-04Z1 is by authorised partners only, and SAMS has not yet granted a territory for Czech Republic. Each application is reviewed on its merits. Because opening a certified Ex handset in an ordinary workshop invalidates its certificate, the partner must be able to support and service the device locally.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
It is designed to IP68 sealing, with glove-friendly controls. Ruggedness is not explosion protection: that depends on the certificates, which are in progress.
The market guide for Czech Republic covers Litvínov and Záluží, Kralupy nad Vltavou, Neratovice, Valašské Meziříčí, among others. Site-level pages are linked below.
Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for Czech Republic.
The Czech Republic is an EU member, so ATEX Directive 2014/34/EU applies to equipment and employers zone workplaces under Directive 1999/92/EC. Refineries such as Litvínov typically also have internal device approval and permit-to-work procedures, so ask the HSE office before bringing phones in.
Czech is the usual site language, and ATEX user instructions are typically expected in the local language of the destination. A Czech-language instruction sheet with the certificate pack often speeds up acceptance. Ask the operator whether it also accepts English documentation for contractors.
FTZÚ in Ostrava-Radvanice is notified body 1026, and Czech engineers recognise it on an Ex certificate, so buyers often ask which body issued one before anything else. The certificate number, issuing body and marking string will be published for checking. No certificate exists yet, as certification is in progress.
Other guides for Czech Republic, other places in Czech Republic, and the pages behind them.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.