Refining
The Pembroke refinery began operating in 1964 and has been owned by Valero since 2011. Cardiff terminal supply by coastal tanker comes from here.
The Milford Haven Waterway in Pembrokeshire is Wales' largest port and a major energy hub. It hosts Valero's Pembroke refinery and the South Hook and Dragon LNG terminals, so Zone 1 work arises at process units, tank farms and gas handling areas. This page explains what to look for in an intrinsically safe smartphone for Wales (Milford Haven Waterway), and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Wales (Milford Haven Waterway): pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Level of protection | ia, ib or ic matched to the zone | ib, for Zone 1 |
| Entity parameters | Uo, Io and Po within the device limits | Published with the certificate |
| Accessories | Chargers and cases certified with the device | Defined at certification |
| Where it applies | Wales (Milford Haven Waterway): Refinery process units, LNG storage and regasification, Crude and product jetties | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Wales. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The companies on site and the hazardous-area types a handset is likely to meet there.
The Pembroke refinery began operating in 1964 and has been owned by Valero since 2011. Cardiff terminal supply by coastal tanker comes from here.
South Hook, opened in 2009 with five storage tanks, is described as Europe's largest LNG terminal. With Dragon LNG, the two terminals can provide up to a quarter of UK gas demand.
Oil refining at Milford Haven began with the first oil terminal and refinery in 1960, and the waterway still carries the jetties, oil terminals and shore processing facilities of the oil and power industries.
Regasified LNG leaves Milford Haven through National Grid's South Wales Gas Pipeline to a distribution point at Tirley in Gloucestershire, so pipeline and compression sites run across south Wales.
By 2018 Wales generated over 3,864 MW of renewable energy from 68,728 projects, and the Welsh Government set a target of meeting 70% of electricity demand from Welsh renewables by 2030.
Milford Haven is the largest port in Wales and the third-largest in the United Kingdom, run by the Milford Haven Port Authority as a trust port that manages Milford Docks, Milford Marina and Pembroke Port.
Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.
The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.
In Wales (Milford Haven Waterway). Rounds at Pembroke cover process units and tank farms, while the LNG terminals involve storage tanks, regasification areas and jetty operations. A handheld designed for intrinsic safety suits those inspections, and also turnaround work where contractors travel in and need to record findings in the area.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.
Likely candidates are refinery process units, lng storage and regasification, crude and product jetties, tank farms. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Yes, Wales is within Great Britain's product rules, where equipment for explosive atmospheres is normally supplied with UKCA marking and CE-marked ATEX equipment has been widely accepted under transitional arrangements. Check the current position and any site-specific rules with the operator before supplying handheld devices.
Wales is mild but wet and windy, with salt spray at coastal terminals such as Milford Haven. Ingress protection, corrosion resistance and condensation tolerance are more important than extreme temperature ratings. Ask the site about its own environmental requirements for portable electronics.
The Milford Haven Waterway in Pembrokeshire hosts Valero's Pembroke refinery, which began operating in 1964, and the South Hook and Dragon LNG terminals. Zone 1 work arises at process units, tank farms and gas handling areas. Confirm requirements with each operator's HSE and procurement teams.
More on Wales, and on other places in United Kingdom.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.